Comparison Dongyin 778402 vs Dongyin 777403
Add to comparison | ![]() | |
|---|---|---|
| Dongyin 778402 | Dongyin 777403 | |
| Outdated Product | from $157.08 | |
| TOP sellers | ||
| Max. performance | 2700 L/h | 2700 L/h |
| Max. head | 65 m | 86 m |
Specs | ||
| Operating principle | centrifugal | centrifugal |
| Max. immersion depth | 60 m | 60 m |
| Max. particle size | 0.2 mm | |
| pH value | 6.5 – 8.5 | 6.5 – 8.5 |
| Suction system | single stage | multistage |
| Oulet size | 1" | 1" |
| Max. liquid T | 35 °С | 35 °С |
Motor | ||
| Power consumption | 550 W | 550 W |
| Mains voltage | 230 В | 230 В |
| Power cable length | 35 m | 40 m |
General specs | ||
| Country of origin | Ukraine | Ukraine |
| Impeller material | technopolymer | technopolymer |
| Dimensions | Ø80 mm | |
| Added to E-Catalog | december 2018 | august 2016 |
Compare Dongyin 778402 and 777403
You may be interested in
My comparisons
Dongyin 77840 often compared
Glossary
Max. head
The maximum head is the maximum height to which the pump can raise water during operation (the highest height of the water column that it can support). This parameter describes the pressure created during operation, but since the operation of well pumps is directly related mainly to lifting liquid to a great height, it is easier to use head data in metres than pressure data. However, if necessary, one can be easily translated into another — 10 m of pressure corresponding to a pressure of 1 bar.
When choosing a pump for this parameter, it is not necessary to chase a large pressure, but it is necessary to take into account several factors.
The first of these is the actual height to which the water must be raised; it can be determined by adding the immersion depth of the pump and the height of the highest draw-off point above the ground. The immersion depth is displayed taking into account the so-called dynamic water level in the well — i.e. distance from the surface of the earth to the water surface during continuous operation of the pump (this indicator is greater than the static level, since when the water is pumped out, its level decreases). The dynamic level is usually indicated in the well passport; the pump should be at least a metre deep underwater, plus a margin of 2 – 3 m should be taken as an adjustment for seasonal level fluctuations. Accordingly, for a well with a dynamic depth of 40 m, supplying a house with...an upper draw-off point of 6 m above the ground, the total height difference will be at least 40 + 6 + 4 = 50 m.
The second point is the hydraulic resistance of the system. Even with horizontal pipes, pressure is required to move fluid through them; usually, when calculating, it is assumed that for every 10 m of the pipeline, 0.1 bar, or 1 m of head, is required. For a water supply system inside an average house, resistance losses are about 5 m of head (0.5 bar). Accordingly, if in our example the house is located 10 m from the well, then the margin to overcome the resistance should be at least 1 + 5 = 6 m of head.
And the third point is the pressure at the points of water intake because the pump must not only “push” the water to the tap, but also provide pressure at the outlet. Here, the optimal values may be different depending on the situation. For example, let's take at least 1 atm (1 bar), which corresponds to 10 m of pressure.
Thus, in our example, the pump head must be at least 50 m (height difference) + 6 m (resistance) + 10 m (outlet head) = 66 m. Of course, this is a calculation for the most general case; in special situations, the formulas may differ, so it makes sense to refer to special sources for them.
When choosing a pump for this parameter, it is not necessary to chase a large pressure, but it is necessary to take into account several factors.
The first of these is the actual height to which the water must be raised; it can be determined by adding the immersion depth of the pump and the height of the highest draw-off point above the ground. The immersion depth is displayed taking into account the so-called dynamic water level in the well — i.e. distance from the surface of the earth to the water surface during continuous operation of the pump (this indicator is greater than the static level, since when the water is pumped out, its level decreases). The dynamic level is usually indicated in the well passport; the pump should be at least a metre deep underwater, plus a margin of 2 – 3 m should be taken as an adjustment for seasonal level fluctuations. Accordingly, for a well with a dynamic depth of 40 m, supplying a house with...an upper draw-off point of 6 m above the ground, the total height difference will be at least 40 + 6 + 4 = 50 m.
The second point is the hydraulic resistance of the system. Even with horizontal pipes, pressure is required to move fluid through them; usually, when calculating, it is assumed that for every 10 m of the pipeline, 0.1 bar, or 1 m of head, is required. For a water supply system inside an average house, resistance losses are about 5 m of head (0.5 bar). Accordingly, if in our example the house is located 10 m from the well, then the margin to overcome the resistance should be at least 1 + 5 = 6 m of head.
And the third point is the pressure at the points of water intake because the pump must not only “push” the water to the tap, but also provide pressure at the outlet. Here, the optimal values may be different depending on the situation. For example, let's take at least 1 atm (1 bar), which corresponds to 10 m of pressure.
Thus, in our example, the pump head must be at least 50 m (height difference) + 6 m (resistance) + 10 m (outlet head) = 66 m. Of course, this is a calculation for the most general case; in special situations, the formulas may differ, so it makes sense to refer to special sources for them.
Max. particle size
The largest size of solids in the pumped water that the pump can handle without failure. It is one of the parameters characterizing the unit's ability to work with dirty water (along with the content of mechanical impurities, see below): the larger the particles, the more reliable the pump and the lower the likelihood of it breaking down due to pollution. This point is especially relevant for recently drilled wells, where the water has not yet had time to clear.
Suction system
— Single stage. Suction system with one impeller or similar element. Although this design loses to multistage in terms of efficiency and power, at the same time, its characteristics are quite enough for most entry-level and mid-level pumps; at the same time, single-stage units are simpler and cheaper.
— Multistage. This suction system consists of several impellers (or other similar parts that directly provide suction). Such pumps are noticeably superior to single-stage ones, they provide powerful pressure and are less sensitive to impurities. At the same time, multistage systems are quite expensive.
— Multistage. This suction system consists of several impellers (or other similar parts that directly provide suction). Such pumps are noticeably superior to single-stage ones, they provide powerful pressure and are less sensitive to impurities. At the same time, multistage systems are quite expensive.
Power cable length
The length of the standard power cable provided in the design of the pump.
Ideally, the length of this cable should not be less than the maximum immersion depth — this will ensure maximum ease of connection: the connection point of the cable to the mains will be above the water (in the best case, even outside the well), and you will not have to worry about insulation. At the same time, for several reasons, many pumps are equipped with rather short cords — about 1.5-2 m, and not long cables; in such cases, it is necessary to use special waterproof equipment.
Ideally, the length of this cable should not be less than the maximum immersion depth — this will ensure maximum ease of connection: the connection point of the cable to the mains will be above the water (in the best case, even outside the well), and you will not have to worry about insulation. At the same time, for several reasons, many pumps are equipped with rather short cords — about 1.5-2 m, and not long cables; in such cases, it is necessary to use special waterproof equipment.