TALLPOWER TP400 400 W
Fossibot SP420 420 W
TALLPOWER TP400 400 WFossibot SP420 420 W
Compare prices 2Compare prices 2
TOP sellers
Featuresportableportable
Typemonocrystallinemonocrystalline
Specs (STC)
STC Power (Pmax)400 W420 W
Nominal voltage (Vmp)18 В32 В
Nominal power (Imp)22.2 А13.1 А
Open-circuit voltage (Voc)21.6 В38.4 В
Short circuit current (Isc)26.67 А15.7 А
Efficiency24 %23.4 %
Features
MC4 connector
Folding design
Support foot
Suspension system
WaterproofIP65IP67
Operating temperature-10 °C ~ +65 °C
General
Dimensions785x2400x30 mm2231x1036 mm
Folded size785x600x75 mm1036x550 mm
Weight12.5 kg13.97 kg
In boxcable
Added to E-Catalogjune 2025august 2023
Compare TALLPOWER TP400 and Fossibot SP420
Glossary

Specs (STC)

Standard Test Conditions (STC) are standard test conditions that reflect the operation of a solar panel under ideal conditions. As part of the tests, the weather of a clear sunny day with an air temperature of +25 °C, no wind, solar intensity of 1000 W/m² and an emission spectrum relative to air mass of 1.5 is simulated. The surface of the solar cell must be placed strictly perpendicular to the rays from the celestial body. Note that in real operation of the solar panel, such conditions are extremely rare. However, in general, the characteristics of the STC allow us to evaluate the "passport" parameters of the energy storage device.

STC Power (Pmax)

The amount of electricity in watts that a solar panel produces in one hour in tests using the STC method. The panel must provide the declared number of watts during normal operation.

Nominal voltage (Vmp)

The voltage reading on the voltmeter during a solar panel test at the nominal power level according to the STC method. This parameter, Vmp, stands for Voltage at Maximum Power and is measured in volts. It helps determine which type of batteries the panel is designed for — either 12 V or 24V.

Nominal power (Imp)

Ammeter reading during solar panel testing under STC conditions. The value of the rated current Imp (Current at Maximum Power) is measured in amperes.

Open-circuit voltage (Voc)

The voltage generated by the solar battery in idle mode, that is, without connecting the load. Behind the abbreviation Voc stands for Voltage Open Circuit.

Short circuit current (Isc)

The current value under the condition of zero voltage (Short Circuit Current).

Efficiency

Percentage of the maximum solar panel power to the incident radiation power produced. The efficiency parameter allows you to determine how efficiently the panel PV module converts solar energy into direct electric current.

Waterproof

The level of protection is indicated by two digits according to the IP standard. The first digit indicates the protection against dust (maximum 6), the second indicates the degree of protection against water (maximum 8). The maximum degree of protection according to this standard is IP68, that is, complete tightness. There are also markings of the IPX4 type, where the first digit is not spelled out - this means that the solar panel has not been officially certified for dust resistance.

Operating temperature

The temperature range in which the solar module functions normally. Exceeding the specified norms in any of the directions leads to a decrease in the productivity of energy generation, accelerated degradation of the panel, and the appearance of microcracks on its surface. For most solar panels, the operating temperature range is -40°C to +85°C.