USA
Catalog   /   Home & Renovation   /   Electrical Equipment   /   Voltage Monitoring Relays

Comparison DigiTOP VP-16SE vs DigiTOP V-protector VP-16AS

Add to comparison
DigiTOP VP-16SE
DigiTOP V-protector VP-16AS
DigiTOP VP-16SEDigiTOP V-protector VP-16AS
Outdated ProductOutdated Product
User reviews
0
1
0
1
TOP sellers
Devicevoltage Monitoring Relaysvoltage Monitoring Relays
Voltagevariablevariable
Number of phases11
Mountinto socketinto socket
Specs
Power3.5 kVA3.5 kVA
Maximum current16 А16 А
Voltage measuring range100 – 400 В50 – 400 В
Measurement accuracy (±)1 %2.2 %
Cut-off time (lower limit)0.02 с0.02 с
Off time (upper limit)0.02 с0.02 с
Reclosing delay5 – 600 с5 – 600 с
Lower cut-off limit120 – 200 В120 – 200 В
Upper cut-off limit210 – 270 В210 – 270 В
Functions
display
operation indicator
fault memory
display
operation indicator
fault memory
General
Adjustmentdigitaldigital
Protection levelIP20IP20
Dimensions107x62x80 mm
Added to E-Catalogmay 2022december 2017
Glossary

Voltage measuring range

Voltage measurement range supported by the device.

Many modern control relays are equipped with digital displays, which can display, including current voltage; this parameter specifies the operating range of the built-in voltmeter. In this case, the voltage measurement range can be noticeably wider than the difference between the smallest minimum and the largest maximum shutdown threshold (see below). This allows you to use the relay also for online diagnostics of the network status.

For a current relay (see "Device") in this case, the range of operating voltages can be given directly — the voltage at which the device can normally perform its functions.

Measurement accuracy (±)

Measurement accuracy provided by the device. In this case, different types of measurements may be implied, depending on the purpose of the relay (see "Device"). Note that in power relays and multifunctional devices, the measurement accuracy for voltage and current is usually the same, and a common parameter is given in the characteristics for them.

Accuracy is indicated by the maximum measurement error provided by the device. First of all, the operation accuracy depends on this parameter: the lower the error, the smaller the actual deviations from the specified operation parameters. For modern control relays, an indicator of 3 – 5% is considered acceptable, 1.5 – 3% is not bad, 1 – 1.5% is good, less than 1% is excellent. However, in fact, it is also worth choosing according to this parameter, taking into account how sensitive the connected load is to the accuracy of the specified operation parameters.

Also note that many modern relays are equipped with digital displays that can display various parameters. In such models, the measurement accuracy also determines the accuracy of the readings of such a built-in "tester".
DigiTOP V-protector VP-16AS often compared