USA
Catalog   /   Home & Renovation   /   Autonomous Power Supply   /   Inverters & Controllers

Comparison Must PV18-3224 PRO vs Must PV18-1512 VPM

Add to comparison
Must PV18-3224 PRO
Must PV18-1512 VPM
Must PV18-3224 PROMust PV18-1512 VPM
Expecting restockOutdated Product
User reviews
0
1
0
0
TOP sellers
Dry contact
Device typehybrid inverteroff-grid inverter
Network type1 phase (230 V)1 phase (230 V)
Maximum efficiency90 %98 %
AC input / output
Rated power3200 VA1500 VA
Rated power3200 W1500 W
Peak power6400 W3000 W
Rated AC current6.5 A
Maximum AC power27.5 А
Output waveformpure sinepure sine
Batteries and DC charging
Connection voltage24 В12 В
Number of battery inputs1 шт1 шт
Maximum charge current100 А70 А
Solar PV panels
Max. power4 kW0.72 kW
Operating voltage PV60 – 320 В15 – 130 В
Controller1xMMPT1xMMPT
Number of strings11
Features and control
Functions
UPS function
generator connection
UPS function
generator connection
Control interfaces
Wi-Fi
USB
RS485
USB
RS485
Protection
short circuit protection
↑ or ↓ battery voltage protection
overload protection
short circuit protection
↑ or ↓ battery voltage protection
overload protection
General
Displaymonochromemonochrome
Coolingactive (fans)active (fans)
Casing protection classIP20IP21
Operating temperature0 °C ~ +50 °C0 °C ~ +50 °C
Dimensions367x290x111 mm318x255x110 mm
Weight5.5 kg
Added to E-Catalognovember 2024july 2024
Glossary

Device type

Autonomous inverter. Voltage and power converters that are not connected to an external electrical network. They are supposed to be used as part of autonomous photovoltaic systems - such inverters generate electricity, which is spent exclusively for the needs of the household. It can be consumed directly by household appliances or accumulated in batteries. This type of inverter is often called off grid.

Network inverter. Inverters operating synchronously with the external power supply network. They are designed to convert solar energy into alternating power with the parameters of the general network. Grid-connected inverters are used in battery-free systems - all generated energy is used for own consumption, and the excess is transferred to the network at a “feed-in tariff”. To do this, some indicators of generated electricity are adjusted, in particular, amplitude differences are eliminated, the network frequency is equalized, etc. Grid-tied inverters are also known as on-grid inverters.

Hybrid inverter. Battery-grid inverters are peculiar hybrids of autonomous and network converters. Actually, this is where the name hybrid comes from. Inverters of this type work with battery chains, and excess electricity is sent to the general network. This ensures the energy independence of the system based on solar panels with the ability to use the energy a...ccumulated in the batteries without disconnecting from the network. For example, if DC power is prioritized, power is primarily supplied from batteries, and any energy shortages are supplied from the external grid. This comes in handy in case of bad weather conditions or insufficient power generated by solar panels. If electricity is generated in excess, the excess energy is released into the general network at a “feed-in tariff”.

Inverter for campers (motorhomes). Such narrow-niche inverters usually work in conjunction with a branded charging station - while staying at a campsite, it charges the vehicle’s battery. And while driving, such inverters are connected to the car’s alternating power generator and with their help, the energy reserves in the battery cells of the charging station are replenished.

Maximum efficiency

Inverter efficiency for solar panels.

The efficiency indicator is the percentage ratio between the amount of energy that the device delivers to the load and the energy consumed from the solar panel. The higher this parameter, the more efficient the operation of the device and the lower the losses during conversion. In modern inverters for solar panels, efficiency values of up to 90% are considered average, and above 90% are considered good.

Rated power

The rated output power of the inverter, expressed in volt-amperes (VA). Essentially, this value is equivalent to power in watts (W).

This parameter refers to the power that the device can continuously deliver to consumers. When choosing based on this parameter, ensure that the rated power of the inverter exceeds the expected load power by approximately 15-20%. Additionally, keep in mind that some electrical appliances (particularly those with electric motors, such as vacuum cleaners, refrigerators, etc.) consume significantly more energy at startup than during regular operation. For such loads, it's important to check the peak power of the inverter (see the relevant paragraph) — it should be higher than the starting power of the load.

Rated power

The rated output power of the inverter, expressed in watts (W).

This parameter means the power that the device can provide to consumers for an unlimited time. It is necessary to choose according to this indicator so that the rated power of the inverter covers the power consumption of the expected load by approximately 15-20%. It is also worth considering that some electrical appliances (in particular, units with electric motors - vacuum cleaners, refrigerators, etc.) consume significantly more energy when starting up than after entering the mode. For such a load, it is also necessary to clarify the peak power of the inverter (see the corresponding paragraph) - it should be higher than the starting power of the load.

Peak power

The highest total output power in watts (W) that the inverter can deliver to a load for a relatively short period of time, on the order of 2 to 3 seconds. As a rule, this power is 30 - 50% more than the rated power (see above). The peak load value can be useful when calculating how the inverter works together with appliances that consume a lot of energy at start-up (vacuum cleaners, borehole pumps, power tools, etc.). The rule here is simple - the peak power of the inverter must not be lower than the starting power of the load.

Rated AC current

The current strength that the device is capable of stably and safely delivering when operating in rated mode (i.e. for the longest possible time without the risk of overloads and failures). The indicator is expressed in Amperes (A).

Maximum AC power

The maximum current in amperes (A) that the inverter, when operating, is capable of outputting without overloads or failures.

Connection voltage

The efficiency of the solar system, laid down by the manufacturer of the inverter, directly depends on this parameter. The following battery voltage options are most widely used: 12 V, 24 V and 48 V.

Maximum charge current

The maximum amount of direct current in amperes that the inverter can convert. If the solar panel produces a current exceeding this value, the inverter simply does not use it. This is often justified when connecting an inverter to high-power solar panels - the maximum input current of the inverter is reduced to acceptable values so that moderate-sized wires can be used to transmit energy.
Must PV18-3224 PRO often compared