Comparison Must PV18-1512 VPM vs Anern AN-SCI02-Azure-2000

Add to comparison
Must PV18-1512 VPM
Anern AN-SCI02-Azure-2000
Must PV18-1512 VPMAnern AN-SCI02-Azure-2000
Outdated ProductOutdated Product
User reviews
0
1
0
0
TOP sellers
Device typeoff-grid inverteroff-grid inverter
Network type1 phase (230 V)1 phase (230 V)
Maximum efficiency98 %
AC input / output
Rated power1500 VA2000 VA
Rated power1500 W1600 W
Peak power3000 W3200 W
Rated AC current6.5 A
Output waveformpure sinepure sine
Batteries and DC charging
Connection voltage12 В12 В
Number of battery inputs1 шт1 шт
Maximum charge current70 А80 А
Solar PV panels
Max. power0.72 kW2 kW
Operating voltage PV15 – 130 В
Controller1xMMPT1xMMPT
Number of strings11
Features and control
Functions
UPS function
generator connection
UPS function
built-in monitoring
Control interfaces
USB
RS485
Wi-Fi
Protection
short circuit protection
↑ or ↓ battery voltage protection
overload protection
reverse polarity protection
short circuit protection
↑ or ↓ battery voltage protection
overload protection
overheat protection
General
Displaymonochromemonochrome
Coolingactive (fans)active (fans)
Casing protection classIP21
Operating temperature0 °C ~ +50 °C
Dimensions318x255x110 mm348x270x95 mm
Weight5.5 kg4.4 kg
Added to E-Catalogjuly 2024july 2024
Glossary

Maximum efficiency

Inverter efficiency for solar panels.

The efficiency indicator is the percentage ratio between the amount of energy that the device delivers to the load and the energy consumed from the solar panel. The higher this parameter, the more efficient the operation of the device and the lower the losses during conversion. In modern inverters for solar panels, efficiency values of up to 90% are considered average, and above 90% are considered good.

Rated power

The rated output power of the inverter, expressed in volt-amperes (VA). Essentially, this value is equivalent to power in watts (W).

This parameter refers to the power that the device can continuously deliver to consumers. When choosing based on this parameter, ensure that the rated power of the inverter exceeds the expected load power by approximately 15-20%. Additionally, keep in mind that some electrical appliances (particularly those with electric motors, such as vacuum cleaners, refrigerators, etc.) consume significantly more energy at startup than during regular operation. For such loads, it's important to check the peak power of the inverter (see the relevant paragraph) — it should be higher than the starting power of the load.

Rated power

The rated output power of the inverter, expressed in watts (W).

This parameter means the power that the device can provide to consumers for an unlimited time. It is necessary to choose according to this indicator so that the rated power of the inverter covers the power consumption of the expected load by approximately 15-20%. It is also worth considering that some electrical appliances (in particular, units with electric motors - vacuum cleaners, refrigerators, etc.) consume significantly more energy when starting up than after entering the mode. For such a load, it is also necessary to clarify the peak power of the inverter (see the corresponding paragraph) - it should be higher than the starting power of the load.

Peak power

The highest total output power in watts (W) that the inverter can deliver to a load for a relatively short period of time, on the order of 2 to 3 seconds. As a rule, this power is 30 - 50% more than the rated power (see above). The peak load value can be useful when calculating how the inverter works together with appliances that consume a lot of energy at start-up (vacuum cleaners, borehole pumps, power tools, etc.). The rule here is simple - the peak power of the inverter must not be lower than the starting power of the load.

Rated AC current

The current strength that the device is capable of stably and safely delivering when operating in rated mode (i.e. for the longest possible time without the risk of overloads and failures). The indicator is expressed in Amperes (A).

Maximum charge current

The maximum amount of direct current in amperes that the inverter can convert. If the solar panel produces a current exceeding this value, the inverter simply does not use it. This is often justified when connecting an inverter to high-power solar panels - the maximum input current of the inverter is reduced to acceptable values so that moderate-sized wires can be used to transmit energy.

Max. power

The maximum allowable input power from solar panels, expressed in kilowatts (kW). Let us remember that 1 kW contains 1000 W.

When selecting an inverter based on this indicator, they are based on the total power of the solar panels involved in generating electricity. Moreover, it often makes sense to select models with an inverter input power slightly less than the maximum power of solar panels - for example, if they are shaded part of the time or for other reasons do not receive enough sunlight during the day. The power of the solar battery should not exceed the power of the inverter by more than 30%. However, for some inverters the excess can be only 10%, while for others it can be up to 100%. It is better to clarify this point in advance.

Operating voltage PV

The operating range of the inverter is usually located between the starting voltage and the maximum voltage. This interval is indicated in volts.

Functions

UPS function. Inverters with a UPS function automatically switch to battery-powered mode when there is insufficient power generation from solar panels or in cases where the main power source is disconnected. This ensures load redundancy. Note that switching may not occur instantly, but with a certain delay (about 10-30 ms).

Connecting the generator. Inverters that support the generator connection function significantly increase the reliability and efficiency of autonomous solar energy systems. In practice, the function can be implemented in several basic ways. First, the system can automatically turn the generator on and off depending on the battery charge level or current power consumption, ensuring efficient use of resources and minimizing fuel consumption. Secondly, switching the load to the generator can be carried out when there is a shortage of electricity generation from solar panels. And thirdly, the generator can be used to maintain an optimal battery charge level so that the system is in full readiness at any time.

Parallel connection. The inverter has special connectors through which two or more devices can be connected to a single electrical network. Parallel connection is used when one inverter is not able to pull the entire load from solar panels and the input power exceeds the capabilities of the device itself.

Built-in monitoring. The presence of a built-in monitoring module on board the inverter, which collects information about the productivity of solar panels, allows you to monitor energy production and consumption, as well as monitor the performance of the system as a whole. Moreover, these parameters can often be viewed and controlled in real time (including through a mobile application for a smartphone). The monitoring module is usually connected to the Internet via a Wi-Fi network.
Must PV18-1512 VPM often compared