USA
Catalog   /   Home & Renovation   /   Autonomous Power Supply   /   Inverters & Controllers

Comparison Luminous NXG 1100 vs Deye SUN-5K-SG03LP1-EU

Add to comparison
Luminous NXG 1100
Deye SUN-5K-SG03LP1-EU
Luminous NXG 1100Deye SUN-5K-SG03LP1-EU
Outdated ProductOutdated Product
TOP sellers
Device typehybrid inverterhybrid inverter
Network type1 phase (230 V)1 phase (230 V)
Maximum efficiency80 %97.6 %
Euro efficiency96.5 %
AC input / output
Rated power850 VA5500 VA
Rated power850 W5000 W
Peak power1700 W10000 W
Rated AC current21.7 A
Maximum AC power23.9 А
Output waveformpure sinepure sine
Batteries and DC charging
Connection voltage12 В48 В
Number of battery inputs1 шт1 шт
Maximum charge current40 А120 А
Solar PV panels
Max. power1 kW6.5 kW
Operating voltage PV370 В
Short circuit current34 А
Controller2xMMPT
Number of strings1
Features and control
Functions
UPS function
 
Control interfaces
 
Wi-Fi
RS485
Protection
short circuit protection
↑ or ↓ battery voltage protection
overload protection
overheat protection
reverse polarity protection
short circuit protection
↑ or ↓ battery voltage protection
overload protection
overheat protection
General
Displayis absentcolour
Coolingactive (fans)active (fans)
Noise level30 dB
Casing protection classIP65
Operating temperature-40 °C ~ +60 °C
Dimensions135x375x315 mm330x580x232 mm
Weight11.5 kg20.5 kg
Added to E-Catalogjanuary 2024may 2023
Glossary

Maximum efficiency

Inverter efficiency for solar panels.

The efficiency indicator is the percentage ratio between the amount of energy that the device delivers to the load and the energy consumed from the solar panel. The higher this parameter, the more efficient the operation of the device and the lower the losses during conversion. In modern inverters for solar panels, efficiency values of up to 90% are considered average, and above 90% are considered good.

Euro efficiency

The European inverter efficiency is measured based on several load values (e.g. 10%, 30%, 50%, 100%), which better reflects the actual operating conditions of the device. Indeed, in fact, inverters rarely operate at full power in constant mode. To calculate the Euro index, the weighted average of the inverter efficiency at different load levels is taken into account. Note that there is no single generally accepted formula here - it may vary depending on the specific standard or equipment manufacturer. Nevertheless, Euro efficiency allows you to more accurately assess the efficiency of the inverter under conditions of partial and full power use

Rated power

The rated output power of the inverter, expressed in volt-amperes (VA). Essentially, this value is equivalent to power in watts (W).

This parameter refers to the power that the device can continuously deliver to consumers. When choosing based on this parameter, ensure that the rated power of the inverter exceeds the expected load power by approximately 15-20%. Additionally, keep in mind that some electrical appliances (particularly those with electric motors, such as vacuum cleaners, refrigerators, etc.) consume significantly more energy at startup than during regular operation. For such loads, it's important to check the peak power of the inverter (see the relevant paragraph) — it should be higher than the starting power of the load.

Rated power

The rated output power of the inverter, expressed in watts (W).

This parameter means the power that the device can provide to consumers for an unlimited time. It is necessary to choose according to this indicator so that the rated power of the inverter covers the power consumption of the expected load by approximately 15-20%. It is also worth considering that some electrical appliances (in particular, units with electric motors - vacuum cleaners, refrigerators, etc.) consume significantly more energy when starting up than after entering the mode. For such a load, it is also necessary to clarify the peak power of the inverter (see the corresponding paragraph) - it should be higher than the starting power of the load.

Peak power

The highest total output power in watts (W) that the inverter can deliver to a load for a relatively short period of time, on the order of 2 to 3 seconds. As a rule, this power is 30 - 50% more than the rated power (see above). The peak load value can be useful when calculating how the inverter works together with appliances that consume a lot of energy at start-up (vacuum cleaners, borehole pumps, power tools, etc.). The rule here is simple - the peak power of the inverter must not be lower than the starting power of the load.

Rated AC current

The current strength that the device is capable of stably and safely delivering when operating in rated mode (i.e. for the longest possible time without the risk of overloads and failures). The indicator is expressed in Amperes (A).

Maximum AC power

The maximum current in amperes (A) that the inverter, when operating, is capable of outputting without overloads or failures.

Connection voltage

The efficiency of the solar system, laid down by the manufacturer of the inverter, directly depends on this parameter. The following battery voltage options are most widely used: 12 V, 24 V and 48 V.

Maximum charge current

The maximum amount of direct current in amperes that the inverter can convert. If the solar panel produces a current exceeding this value, the inverter simply does not use it. This is often justified when connecting an inverter to high-power solar panels - the maximum input current of the inverter is reduced to acceptable values so that moderate-sized wires can be used to transmit energy.
Luminous NXG 1100 often compared
Deye SUN-5K-SG03LP1-EU often compared