USA
Catalog   /   Home & Renovation   /   Autonomous Power Supply   /   Inverters & Controllers

Comparison PowMr POW-HVM3.2H-24V vs PowMr POW-HVM3.2H-24V-N

Add to comparison
PowMr POW-HVM3.2H-24V
PowMr POW-HVM3.2H-24V-N
PowMr POW-HVM3.2H-24VPowMr POW-HVM3.2H-24V-N
Outdated ProductOutdated Product
TOP sellers
Device typehybrid inverteroff-grid inverter
Network type1 phase (230 V)1 phase (230 V)
Maximum efficiency94 %94 %
AC input / output
Rated power3200 VA3200 VA
Rated power3000 W3000 W
Peak power6400 W6400 W
Output waveformpure sinepure sine
Batteries and DC charging
Connection voltage24 В24 В
Number of battery inputs1 шт1 шт
Maximum charge current80 А80 А
Solar PV panels
Max. power3 kW3 kW
Operating voltage PV90 – 430 В30 – 400 В
Features and control
Functions
UPS function
generator connection
UPS function
generator connection
Control interfaces
RS232
RS485
RS232
Protection
short circuit protection
overload protection
short circuit protection
↑ or ↓ battery voltage protection
overload protection
overheat protection
General
Displaymonochromemonochrome
Coolingactive (fans)
Operating temperature-10 °C ~ +50 °C-10 °C ~ +50 °C
Dimensions348x270x95 mm357x273x95 mm
Weight5.4 kg4.8 kg
Added to E-Catalogdecember 2023november 2023
Glossary

Device type

Autonomous inverter. Voltage and power converters that are not connected to an external electrical network. They are supposed to be used as part of autonomous photovoltaic systems - such inverters generate electricity, which is spent exclusively for the needs of the household. It can be consumed directly by household appliances or accumulated in batteries. This type of inverter is often called off grid.

Network inverter. Inverters operating synchronously with the external power supply network. They are designed to convert solar energy into alternating power with the parameters of the general network. Grid-connected inverters are used in battery-free systems - all generated energy is used for own consumption, and the excess is transferred to the network at a “feed-in tariff”. To do this, some indicators of generated electricity are adjusted, in particular, amplitude differences are eliminated, the network frequency is equalized, etc. Grid-tied inverters are also known as on-grid inverters.

Hybrid inverter. Battery-grid inverters are peculiar hybrids of autonomous and network converters. Actually, this is where the name hybrid comes from. Inverters of this type work with battery chains, and excess electricity is sent to the general network. This ensures the energy independence of the system based on solar panels with the ability to use the energy a...ccumulated in the batteries without disconnecting from the network. For example, if DC power is prioritized, power is primarily supplied from batteries, and any energy shortages are supplied from the external grid. This comes in handy in case of bad weather conditions or insufficient power generated by solar panels. If electricity is generated in excess, the excess energy is released into the general network at a “feed-in tariff”.

Inverter for campers (motorhomes). Such narrow-niche inverters usually work in conjunction with a branded charging station - while staying at a campsite, it charges the vehicle’s battery. And while driving, such inverters are connected to the car’s alternating power generator and with their help, the energy reserves in the battery cells of the charging station are replenished.

Operating voltage PV

The operating range of the inverter is usually located between the starting voltage and the maximum voltage. This interval is indicated in volts.

Control interfaces

Connection interfaces provided in the inverter design for solar panels.

- RS232. A specialized communication interface used to directly connect the inverter to a computer. As a rule, the interface provides the ability to monitor solar generation systems around the clock using a local network. Also, the RS232 connector can be used to communicate several inverters with each other, or, less often, for software updates or service testing.

- RS485. A connector often used to connect several inverters to a central hub, which, in turn, connects to a computer. This connection can be useful for setting up a solar generation system or sending monitoring data over the network.

- USB. A standard USB port is often used for configuring equipment via a wired connection to a computer or for inverter firmware updates.

- LAN (RJ45). The presence of a LAN connector (RJ45) in the inverter design. Such ports are standardly used for wired connections in computer networks using a twisted pair cable.

- Wi-Fi. Wi-Fi communication module for wireless connection of the inverter to a computer, laptop or mobile phone. Using specialized software, you can receive monitoring data from the inverter directly “over the air” - transmitting information over a Wi-Fi network eliminates the...fuss with wires.

Bluetooth. Option to wirelessly pair the inverter with smartphones, tablets or laptops via Bluetooth. Thanks to data synchronization, the user will be able to monitor equipment performance and remotely control the inverter within range of the Bluetooth wireless network.

Protection

Overload protection. A protection system against connecting an off-design load whose power consumption exceeds the capabilities of the inverter for solar panels. In such situations, the power to the outlets is automatically turned off, since overloading the device promises failure and even fire. Triggering of the protection is usually accompanied by a sound and/or light signal.

Overheat protection. This protection is triggered when the temperature inside the inverter rises critically. When such situations occur, the device turns off, which avoids breakdowns. In the future, some models will automatically turn on when the temperature normalizes, while others must be turned on manually. Note that overheating is caused not only by malfunctions, but also by completely normal reasons - for example, long-term operation at high air temperatures. Typically, overheating protection is accompanied by a sound and/or light signal.

Protection against ↑ or ↓ battery voltage. A protection system that prevents the inverter from being supplied with excessively high or excessively low voltage from the batteries. When the operating voltage range is exceeded, the device automatically turns off to avoid breakdowns and other troubles. A sound and/or light signal can warn of protection activation.

Short circuit protection. Protec...tion that is triggered when the output current increases critically (for example, due to a foreign metal object getting between live parts of the load). To avoid breakdowns and failure, the power at the inverter output is automatically turned off. Triggering of the protection system is usually accompanied by a sound and/or light signal.

Reverse polarity protection. Protection system in case of incorrect polarity of connection. If the “plus” and “minus” do not match, the inverter is disconnected from the power supply in order to avoid damage to the electronic components. Notification of protection activation is often provided by a sound and/or light signal.

— Protection class. The class of protection against dust and moisture provided by the inverter housing for solar panels. Indicated according to the IP standard by two numbers: the first (from 1 to 6) means resistance to penetration of foreign objects and dust, the second (from 1 to 8) - protection from moisture. The higher the number, the higher the level of protection provided. Also note that instead of the first digit in the designation of the protection class, “X” may be indicated - for example, IPX7. In this case, the device is not certified for dust protection, although in fact the level of such protection may be quite high. So, in the example with moisture resistance “7”, the case can be completely immersed in water - which means it is closed very tightly from dust.

The IP protection level is especially important to consider when choosing models for outdoor use and installation in rooms with high humidity levels - they are the ones most susceptible to adverse environmental influences. A high IP class will guarantee stable operation of the inverter for solar panels in such difficult conditions.

Cooling

A method of removing heat from the heating elements of the inverter.

Passive cooling. Passive is any type of cooling that does not involve forced heat removal and is carried out through natural heat transfer and convection. Its main advantage is the complete absence of noise. In addition, such devices are cheaper, do not consume energy to operate the cooling system, and take up relatively little space. On the other hand, passive cooling is significantly inferior to active cooling in terms of efficiency, and therefore is poorly suited for powerful devices.

Active cooling (fans). Active cooling involves the forced removal of heat from device components through radiators with fans that “blow away” excess heat outside the case. Such systems are characterized by extremely high efficiency and can be used in inverters of any power. However, you will have to put up with increased noise levels, as well as significant dimensions and weight of the equipment. In addition, fans tend to draw dust into the case, and if they break down, the entire cooling system essentially fails. The cost of inverters with active cooling is significantly higher than models with a passive principle of heat removal from internal components.
PowMr POW-HVM3.2H-24V-N often compared