USA
Catalog   /   Home & Renovation   /   Autonomous Power Supply   /   Inverters & Controllers

Comparison Anern EVO Series SCI-EVO-3200 vs ANENJI ANJ-SP-3200H-24V

Add to comparison
Anern EVO Series SCI-EVO-3200
ANENJI ANJ-SP-3200H-24V
Anern EVO Series SCI-EVO-3200ANENJI ANJ-SP-3200H-24V
Outdated ProductOutdated Product
TOP sellers
Device typehybrid inverterhybrid inverter
Network type1 phase (230 V)1 phase (230 V)
Maximum efficiency98 %98 %
AC input / output
Rated power3200 VA3200 VA
Rated power3000 W3000 W
Peak power6400 W6000 W
Output waveformpure sinepure sine
Batteries and DC charging
Connection voltage24 В24 В
Number of battery inputs1 шт1 шт
Maximum charge current80 А80 А
Solar PV panels
Max. power3 kW3 kW
Operating voltage PV30 – 400 В55 – 450 В
Controller1xMMPT
Features and control
Functions
UPS function
built-in monitoring
UPS function
built-in monitoring
Control interfaces
Wi-Fi
LAN (RJ45)
RS232
RS485
Protection
short circuit protection
overload protection
short circuit protection
overload protection
overheat protection
General
Displaymonochromemonochrome
Coolingactive (fans)
Casing protection classIP21
Operating temperature-10 °C ~ +50 °C-10 °C ~ +55 °C
Dimensions360x270x100 mm405x286x98 mm
Weight5.4 kg5 kg
Added to E-Catalognovember 2023november 2023
Glossary

Peak power

The highest total output power in watts (W) that the inverter can deliver to a load for a relatively short period of time, on the order of 2 to 3 seconds. As a rule, this power is 30 - 50% more than the rated power (see above). The peak load value can be useful when calculating how the inverter works together with appliances that consume a lot of energy at start-up (vacuum cleaners, borehole pumps, power tools, etc.). The rule here is simple - the peak power of the inverter must not be lower than the starting power of the load.

Operating voltage PV

The operating range of the inverter is usually located between the starting voltage and the maximum voltage. This interval is indicated in volts.

Controller

Built-in Maximum Power Point Tracking (MPPT) system for monitoring the maximum power points of photovoltaic modules in solar panels. It determines the most optimal ratio of voltage and current drawn from the solar panels, thereby ensuring maximum performance of individual strings (chains of series-connected panels). An MPPT controller is useful under any external weather changes, allowing solar panels to generate power even in cloudy conditions. Modern inverter models can contain either one or several MPPT trackers (up to six), which allow for the connection of multiple arrays with different orientations and angles of inclination, thereby eliminating the mutual influence of one array on another. Each MPPT controller output is designed to connect one string.

Control interfaces

Connection interfaces provided in the inverter design for solar panels.

- RS232. A specialized communication interface used to directly connect the inverter to a computer. As a rule, the interface provides the ability to monitor solar generation systems around the clock using a local network. Also, the RS232 connector can be used to communicate several inverters with each other, or, less often, for software updates or service testing.

- RS485. A connector often used to connect several inverters to a central hub, which, in turn, connects to a computer. This connection can be useful for setting up a solar generation system or sending monitoring data over the network.

- USB. A standard USB port is often used for configuring equipment via a wired connection to a computer or for inverter firmware updates.

- LAN (RJ45). The presence of a LAN connector (RJ45) in the inverter design. Such ports are standardly used for wired connections in computer networks using a twisted pair cable.

- Wi-Fi. Wi-Fi communication module for wireless connection of the inverter to a computer, laptop or mobile phone. Using specialized software, you can receive monitoring data from the inverter directly “over the air” - transmitting information over a Wi-Fi network eliminates the...fuss with wires.

Bluetooth. Option to wirelessly pair the inverter with smartphones, tablets or laptops via Bluetooth. Thanks to data synchronization, the user will be able to monitor equipment performance and remotely control the inverter within range of the Bluetooth wireless network.

Protection

Overload protection. A protection system against connecting an off-design load whose power consumption exceeds the capabilities of the inverter for solar panels. In such situations, the power to the outlets is automatically turned off, since overloading the device promises failure and even fire. Triggering of the protection is usually accompanied by a sound and/or light signal.

Overheat protection. This protection is triggered when the temperature inside the inverter rises critically. When such situations occur, the device turns off, which avoids breakdowns. In the future, some models will automatically turn on when the temperature normalizes, while others must be turned on manually. Note that overheating is caused not only by malfunctions, but also by completely normal reasons - for example, long-term operation at high air temperatures. Typically, overheating protection is accompanied by a sound and/or light signal.

Protection against ↑ or ↓ battery voltage. A protection system that prevents the inverter from being supplied with excessively high or excessively low voltage from the batteries. When the operating voltage range is exceeded, the device automatically turns off to avoid breakdowns and other troubles. A sound and/or light signal can warn of protection activation.

Short circuit protection. Protec...tion that is triggered when the output current increases critically (for example, due to a foreign metal object getting between live parts of the load). To avoid breakdowns and failure, the power at the inverter output is automatically turned off. Triggering of the protection system is usually accompanied by a sound and/or light signal.

Reverse polarity protection. Protection system in case of incorrect polarity of connection. If the “plus” and “minus” do not match, the inverter is disconnected from the power supply in order to avoid damage to the electronic components. Notification of protection activation is often provided by a sound and/or light signal.

— Protection class. The class of protection against dust and moisture provided by the inverter housing for solar panels. Indicated according to the IP standard by two numbers: the first (from 1 to 6) means resistance to penetration of foreign objects and dust, the second (from 1 to 8) - protection from moisture. The higher the number, the higher the level of protection provided. Also note that instead of the first digit in the designation of the protection class, “X” may be indicated - for example, IPX7. In this case, the device is not certified for dust protection, although in fact the level of such protection may be quite high. So, in the example with moisture resistance “7”, the case can be completely immersed in water - which means it is closed very tightly from dust.

The IP protection level is especially important to consider when choosing models for outdoor use and installation in rooms with high humidity levels - they are the ones most susceptible to adverse environmental influences. A high IP class will guarantee stable operation of the inverter for solar panels in such difficult conditions.

Cooling

A method of removing heat from the heating elements of the inverter.

Passive cooling. Passive is any type of cooling that does not involve forced heat removal and is carried out through natural heat transfer and convection. Its main advantage is the complete absence of noise. In addition, such devices are cheaper, do not consume energy to operate the cooling system, and take up relatively little space. On the other hand, passive cooling is significantly inferior to active cooling in terms of efficiency, and therefore is poorly suited for powerful devices.

Active cooling (fans). Active cooling involves the forced removal of heat from device components through radiators with fans that “blow away” excess heat outside the case. Such systems are characterized by extremely high efficiency and can be used in inverters of any power. However, you will have to put up with increased noise levels, as well as significant dimensions and weight of the equipment. In addition, fans tend to draw dust into the case, and if they break down, the entire cooling system essentially fails. The cost of inverters with active cooling is significantly higher than models with a passive principle of heat removal from internal components.

Casing protection class

The protection class of the housing is traditionally indicated according to the IP standard - the “IP” marking with two numbers. The first describes protection against the penetration of dust and foreign objects. The following options may occur:

— 2. Protection against objects with a thickness of 12.5 mm or more, prevents the penetration of fingers.
— 3. Protection against objects with a thickness of 2.5 mm, in particular many tools.
— 4. Protection from objects with a thickness of 1 mm (most wires).
— 5. Complete protection from contact of the “internals” with foreign objects, resistance to dust (it can penetrate inside the case, but in scanty quantities that do not affect the operation of the device).
— 6. Completely closed housing, preventing dust from getting inside.

The second digit in the IP marking characterizes the degree of protection against moisture:

— 0. Complete absence of any protection; water ingress into the housing is not allowed.
— 1. Protection from vertical drops of water.
— 2. Protection against vertical drops when the body is tilted up to 15° from the standard position.
— 3. Protection against splashes falling on the body at an angle of up to 60° to the horizontal, the minimum indicator that allows us to talk about resistance to rain.
- 4. Protection against splashes from any direction, allows you to safely withstand rain and strong winds.
— 5. Protection from water jets from any...direction, resistance to storms.
— 6. Protection from strong water jets or strong sea waves (when the device can be completely hidden under the wave for a short time).
— 7. Possibility of short-term immersion to a depth of up to 1 m (without the possibility of constant operation in submerged mode).
— 8. possibility of long-term immersion to a depth of more than 1 m (with the possibility of constant operation in submerged mode).

The degree of IP protection is especially important to consider when choosing outdoor models - they are the ones most susceptible to adverse environmental influences. This parameter is also important when placing the inverter in rooms with high humidity levels.

Operating temperature

The range of ambient temperatures in which the solar panel inverter is guaranteed to maintain normal operation. Here it is necessary to focus on the expected minimums and maximums of temperatures. Moreover, for operation in the cold season, it is worth paying close attention to models with the ability to operate at sub-zero temperatures.
Anern EVO Series SCI-EVO-3200 often compared
ANENJI ANJ-SP-3200H-24V often compared