Comparison 2E PC210M15 vs Power Plant JY-3024/15 PPCA08M150S1

Add to comparison
2E PC210M15
Power Plant JY-3024/15 PPCA08M150S1
2E PC210M15Power Plant JY-3024/15 PPCA08M150S1
Outdated ProductOutdated Product
TOP sellers
Product typeextensionextension
Specs
Cable length15 m15 m
Max. power2300 W1800 W
Max. load10 А8 А
Wire section1 mm²1 mm²
Operation indicator
Connection
Plug typeon camera flasheson camera flashes
Grounded sockets (type F)1
Ungrounded sockets (type C)1
Design features
Weight1180 g
Color
Added to E-Catalogjuly 2023january 2018
Glossary

Max. power

The highest power consumption of the connected devices that the surge protector can tolerate without consequences (to be more precise, with which it can work indefinitely without overloads, overheating, etc.).

This limitation is due to the fact that the higher the power at the same voltage, the higher the current passing through the equipment (in this case, through the surge protector); and off-design currents can lead to breakdowns and even accidents. And although in order to avoid these consequences, modern filters often provide various types of protection (see above), however, the operation of protection is still an emergency situation that is best avoided. Therefore, it is worth choosing a model according to this parameter in such a way that the maximum filter power is at least not lower than the total power consumption of the load. And it is best to have a margin of 20 – 30% — this will give additional guarantees in case of various deviations in the operation of the connected equipment.

Separately, it is worth highlighting the situations when the filter is planned to be used for the so-called reactive load — electrical appliances that widely use circuits on capacitors and/or inductors, for example, power tools or refrigeration units. The total power consumption of such devices (written in volt-amperes) can be much higher than the active power (which is indicated in watts). The recommended line filter power in such cases is calculated using special...formulas that can be found in the relevant sources.

Max. load

The maximum current that the surge protector can pass through itself for an unlimited time without the risk of overheating, breakdowns and other troubles.

This parameter is directly related to the maximum power of the filter (see above): power is the current multiplied by the voltage. Thus, for example, for a standard 230 V model with a maximum power of 2200 W, the maximum load will be 10 A. Note that the characteristics of modern filters may not correspond to such calculations — for example, the same 10 A can be claimed for a 2500 W model . However, this is not something extraordinary: the difference in figures may be due to active and reactive power (see "Maximum power"), the characteristics of single-phase filters (without 400 V sockets, see above) can be given both for 230 V, so for 230 V and even 240 V, figures may be rounded for readability, etc.

Anyway, the practical value of the maximum load is the same as the maximum power: it should not be less than the current supplied to the connected electrical appliances (otherwise the protection may trip, or even break). And they use this parameter, along with the maximum power, because in some cases it is easier to evaluate the characteristics of the load (and filter requirements) in terms of current consumption, and not in terms of power.

Grounded sockets (type F)

The number of sockets with type F grounding, provided in the design of the mains filter.

In this case, we are talking about full-size European type F sockets with metal ground clamps on both sides at the edges of the socket. The "socket" in this case means a CEE 7/4 ("Schuko") standard plug. Grounding is required for the safe operation of some types of electrical appliances, in particular, washing machines and other machines that work with water, refrigerators, computers, audio equipment, etc. A detailed list can be found in the reference literature. If you plan to connect such devices through the filter, this filter must have sockets with grounding.

Ungrounded sockets (type C)

The number of sockets without earthing type C, provided in the design of the mains filter.

In this case, it is assumed that the design of the power filter has a European type C socket (or several such sockets) without grounding. In this case, a "socket" means a CEE 7/4 ("Schuko") plug with two round holes in the central plane of the socket. It is worth choosing a model with this function only if the devices that you plan to use with the filter do not require grounding - otherwise, connecting to such an outlet may be unsafe.