Comparison Immergas Victrix Tera V2 24 Plus 24.5 kW vs Immergas Victrix Tera V2 28 24.7 kW

Add to comparison
Immergas Victrix Tera V2 24 Plus 24.5 kW
Immergas Victrix Tera V2 28 24.7 kW
Immergas Victrix Tera V2 24 Plus 24.5 kWImmergas Victrix Tera V2 28 24.7 kW
Expecting restockOutdated Product
TOP sellers
Energy sourcegasgas
Installationwallwall
Typedual-circuit (heating and DHW)dual-circuit (heating and DHW)
Heating area196 m²196 m²
Condensing
Technical specs
Heat output24.5 kW24.7 kW
Power supply230 В230 В
Power consumption90 W90 W
Coolant min. T20 °С20 °С
Coolant max. T90 °С85 °С
Heating circuit max. pressure3 bar3 bar
DHW circuit max. pressure10 bar10 bar
Consumer specs
DHW min. T30 °С30 °С
DHW max. T60 °С60 °С
"Summer" mode
Heated floor mode
Circulation pump
Boiler specs
Efficiency108 %108 %
Combustion chamberclosed (turbocharged)closed (turbocharged)
Flue diameter60/100 mm60/100 mm
Inlet gas pressure20 mbar
Max. gas consumption3.04 m³/h
Expansion vessel capacity5.8 L5.8 L
Expansion vessel pressure1 bar1 bar
Connections
Mains water intake1/2"1/2"
DHW flow1/2"1/2"
Gas supply3/4"3/4"
Central heating flow3/4"3/4"
Central heating return3/4"3/4"
Safety
Safety systems
gas pressure drop
water overheating
flame loss
draft control
frost protection
gas pressure drop
water overheating
flame loss
draft control
frost protection
More specs
Dimensions (HxWxD)748x440x253 mm748x440x253 mm
Weight31.2 kg30.4 kg
Added to E-Catalogjanuary 2025july 2024
Glossary

Heat output

It is the maximum useful power of the boiler.

The ability of the device to heat a room of a particular area directly depends on this parameter; by power, you can approximately determine the heating area, if this parameter is not indicated in the specs. The most general rule says that for a dwelling with a ceiling height of 2.5 – 3 m, at least 100 W of heat power is needed to heat 1 m2 of area. There are also more detailed calculation methods that take into account specific factors: the climatic zone, heat gain from the outside, design features of the heating system, etc.; they are described in detail in special sources. Also note that in dual-circuit boilers (see "Type"), part of the heat generated is used to heat water for the hot water supply; this must be taken into account when evaluating the output power.

It is believed that boilers with a power of more than 30 kW must be installed in separate rooms (boiler rooms).

Coolant max. T

The maximum operating temperature of the heat medium in the boiler system when operating in heating mode.

Inlet gas pressure

It is the optimum gas pressure supplied to the inlet of the boiler system. Most often indicated for natural gas and is about 15-20 mbar. This parameter must match the specs of the gas supply system. However, the pressure in the latter may be higher, which may require the installation of a special gas regulator.

Max. gas consumption

Maximum gas consumption in the boiler with the corresponding energy source (see above). Achieved when the gas heater is operating at full capacity; with reduced power and consumption, respectively, will be lower.

Note that boilers of the same power may differ in gas consumption due to the difference in efficiency. While the more fuel-efficient models tend to cost more, the price difference pays off in gas savings.