Comparison WOLF CGS-2-24/200L 24 kW vs Vaillant ecoTEC plus VUW INT 246/5-5 21.7 kW

Add to comparison
WOLF CGS-2-24/200L 24 kW
Vaillant ecoTEC plus VUW INT 246/5-5 21.7 kW
WOLF CGS-2-24/200L 24 kWVaillant ecoTEC plus VUW INT 246/5-5 21.7 kW
Expecting restock
from $1,399.26 up to $1,652.18
Outdated Product
User reviews
0
2
0
1
TOP sellers
Scheme of work winter-summer. High energy efficiency due to the use of gas condensate. Low NOx emissions. A complete set of protective elements of the security system. Built-in eBus communication bus.
Energy sourcegasgas
Installationwallwall
Typedual-circuit (heating and DHW)dual-circuit (heating and DHW)
Heating area192 m²174 m²
Condensing
Additional equipment
Built-in water heater tank
DHW tank volume200 L
Technical specs
Heat output24 kW21.7 kW
Min. heat output4.2 kW
Power supply230 В230 В
Power consumption135 W70 W
Coolant min. T30 °С
Coolant max. T90 °С85 °С
Heating circuit max. pressure3 bar3 bar
DHW circuit max. pressure10 bar10 bar
Consumer specs
DHW min. T15 °С35 °С
DHW max. T65 °С65 °С
Performance (ΔT ~30 °C)11.5 L/min
"Summer" mode
Circulation pump
Control buseBus
Boiler specs
Efficiency107 %108 %
Combustion chamberclosed (turbocharged)closed (turbocharged)
Flue diameter60/100, 80/125 mm60/100 mm
Inlet gas pressure20 mbar
Max. gas consumption2.79 m³/h
Expansion vessel capacity10 L10 L
Coolant performance860 L/h
Connections
Mains water intake3/4"3/4"
DHW flow3/4"3/4"
Gas supply1/2"1/2"
Central heating flow3/4"3/4"
Central heating return3/4"3/4"
Safety
Safety systems
gas pressure drop
water overheating
flame loss
draft control
gas pressure drop
water overheating
flame loss
draft control
water circulation failure
frost protection
More specs
Dimensions (HxWxD)1462x600x635 mm720x440x338 mm
Weight84 kg35 kg
Added to E-Catalogjanuary 2018august 2014
Glossary

Heating area

A very conditional parameter that slightly characterizes the purpose based on the size of the room. And depending on the height of the ceilings, layout, building design and equipment, actual values may differ significantly. However, this item represents the maximum recommended area of the room that the boiler can effectively heat. However, it is worth considering that different buildings have different thermal insulation properties and modern buildings are much “warmer” than 30-year-old and especially 50-year-old houses. Accordingly, this item is more of a reference nature and does not allow us to fully assess the actual heated area. There is a formula by which you can derive the maximum heating area, knowing the useful power of the boiler and the climatic conditions in which it will be used; For more information on this, see "Useful Power". In our case, the heating area is calculated using the formula “boiler power multiplied by 8”, which is approximately equivalent to use in houses that are several decades old.

Built-in water heater tank

The presence of a built-in water heater tank in the boiler — a storage tank for water used in the hot water supply system. For obvious reasons, this feature is found exclusively in dual-circuit boilers (see "Type"). It provides several advantages over a flow-through design (when the boiler heats water directly in the process of moving through the heat exchanger). Firstly, in the tank, you can constantly keep a supply of ready hot water, and use it even in case of interruptions in the water supply. Secondly, the temperature of the dispensed water is constant, while in instant heating devices fluctuations are possible when the water flow rate changes. Thirdly, the efficiency of work does not depend on the pressure in the water supply. On the other hand, this feature significantly affects the dimensions, weight and price of the boiler.

DHW tank volume

The volume of the DHW tank provided in the boiler.

In this case, we can talk about both built-in tanks (see above), and a separate device supplied in the kit. The first option is found in dual-circuit boilers, and the second is in single-circuit ones (see "Type"). Anyway, the larger the tank, the more water you can keep in reserve, but the larger and heavier the entire boiler or separate tank is. There are special methods that allow you to calculate the optimal tank capacity depending on the number and type of water points, the number of users, etc. Such methods are described in detail in special sources, but we note here that the average value is considered to be about 80 – 100 litres. It is enough for regular use by a family of 3 – 4 people.

Heat output

It is the maximum useful power of the boiler.

The ability of the device to heat a room of a particular area directly depends on this parameter; by power, you can approximately determine the heating area, if this parameter is not indicated in the specs. The most general rule says that for a dwelling with a ceiling height of 2.5 – 3 m, at least 100 W of heat power is needed to heat 1 m2 of area. There are also more detailed calculation methods that take into account specific factors: the climatic zone, heat gain from the outside, design features of the heating system, etc.; they are described in detail in special sources. Also note that in dual-circuit boilers (see "Type"), part of the heat generated is used to heat water for the hot water supply; this must be taken into account when evaluating the output power.

It is believed that boilers with a power of more than 30 kW must be installed in separate rooms (boiler rooms).

Min. heat output

The minimum heat output at which the heating boiler can operate in constant mode. Operation at minimum power allows you to reduce the number of on-and-off cycles that adversely affect the durability of heating boilers.

Power consumption

The maximum electrical power consumed by the boiler during operation. For non-electric models (see Energy source), this power is usually low, as it is required mainly for control circuits and it can be ignored. Regarding electric boilers, it is worth noting that the power consumption in them is most often somewhat higher than the useful one since part of the energy is inevitably dissipated and not used for heating. Accordingly, the ratio of useful and consumed power can be used to evaluate the efficiency of such a boiler.

Coolant min. T

The minimum operating temperature of the heat medium in the boiler system when operating in heating mode.

Coolant max. T

The maximum operating temperature of the heat medium in the boiler system when operating in heating mode.

DHW min. T

The minimum temperature of domestic hot water (DHW) supplied by a dual-circuit boiler. For comparison, we note that water begins to be perceived as warm, starting from 40 °C, and in centralized hot water supply systems, the temperature of hot water is usually about 60 °C (and should not exceed 75 °C). At the same time, in some boilers, the minimum heating temperature can be only 10 °C or even 5 °C. A similar mode of operation is used to protect pipes from freezing during the cold season: the circulation of water with a positive temperature prevents the formation of ice inside and damage to the circuits.

It is also worth keeping in mind that when heated to a given temperature, the temperature difference ("ΔT") may be different — depending on the initial temperature of the cold water. And the performance of the boiler in the DHW mode directly depends on ΔT; see below for performance details.
Vaillant ecoTEC plus VUW INT 246/5-5 often compared