USA
Catalog   /   Home & Renovation   /   Autonomous Power Supply   /   Portable Power Stations

Comparison XO PSA-700 vs EcoFlow RIVER Max

Add to comparison
XO PSA-700
EcoFlow RIVER Max
XO PSA-700EcoFlow RIVER Max
Outdated Product
from $599.00 
Outdated Product
TOP sellers
Main
2 ports USB A, USB A Fast Charge, USB C. Flashlight. Car cigarette lighter port DC5521. X-Stream port for fast charging (500W). NCM - lithium-ion battery, capacity 576 Wh. Jumps up to 1200 watts are allowed. Backlight
In boxcharging stationcharging station
Rated power700 W600 W
Peak power1400 W1200 W
Output waveformsinusoid (PSW)sinusoid (PSW)
UPS function
 /30 мс/
Outputs
Sockets (230 V)22
USB A
2 pcs
5В/2.4А
12 W
2 pcs
5В/2.4А
12 W
USB A (quick charge)
 
 
 
1
5В/2.4A, 9В/2A, 12В/1.5A
18 W
USB type C
1 pcs
5 A
100 W
1 pcs
5 A
100 W
Car cigarette lighter
 /12 H / 10 A/
DC output2x DC5521 (13.6 V / 3 A)
Inputs (station charging)
From solar panels
Input port XT60
Battery and charging time
Battery type
LiFePO4 /32700/
Li-ion NMC
Battery capacity614.4 W*h576 W*h
Charging cycles1500
500 /DOD>80%/
Charging time (socket) 84 min96 min
Charging time (cigarette lighter) 300 min390 min
Charging power (socket)500 W500 W
General
PSUbuilt into the bodybuilt into the body
Display
Backlight
Carrying handle
Operating temperature0 °C ~ +45 °C
Dimensions300x210x200 mm235x288x185 mm
Weight8.1 kg7.7 kg
Added to E-Catalogjanuary 2023september 2022

Rated power

Power that a device can consistently produce for an indefinitely long time without any unpleasant consequences. For normal operation of the charging station, the rated power must be at least 15 - 20% higher than the total power of all devices simultaneously connected to it.

Peak power

Some electrical appliances (in particular, units with electric motors - refrigerators, air conditioners, etc.) consume significantly more energy at startup than after reaching the operating mode. For such a load, the peak power of the charging station must be taken into account - its indicator must be higher than the starting power of the load.

UPS function

Charging stations with UPS function switch consumers to backup power from their own battery, acting as an uninterruptible power supply. In comparison with full-fledged UPSs, switching does not occur instantly, but with a certain delay (about 10-30 ms). To use this function correctly, you must first study the instructions for the charging station, which often describes the correct procedure for connecting the intended consumer devices.

USB A (quick charge)

Full size USB A ports with fast charging support. It allows you to charge your smartphone, tablet or other connected device much faster. The charging process takes place at increased power, and the current and voltage at each stage are regulated in such a way as to remain within the optimal values. However, it should be borne in mind that in our time there are many fast charging technologies and not all of them are compatible with each other.

- The strength of the current. The parameters of the current issued through the USB A fast charging connectors. Note that different voltage and current parameters can be output to different ports of the charging station. This item specifies the current values at a certain voltage (for example, 5 V / 3 A, 9 V / 2 A, 12 V / 1.5 A).

— Power. The maximum power in watts (W) that the charging station is capable of delivering through the USB A fast charging connector to one charging device. High output power allows you to speed up the charging process. However, the appropriate power must be supported by the device being charged - otherwise the speed of the process will be limited by the characteristics of the gadget.

DC output

The presence of a DC connector (or several such outputs) in the device to power external gadgets with direct current. The standard DC jack is round and has a pin in the center. However, its dimensions may differ in depth and diameter. The voltage output to the DC output may be different. The most popular options are 18 - 20 V for powering laptops, 12 V for various specialized devices and automotive electrical accessories.

From solar panels

The ability to charge the device from solar panels ensures the energy independence of a portable power plant. Models with this function can work completely autonomously and do not depend on outlets. Charging from the panels is implemented in the corresponding devices with portable solar panels and charging stations, which are structurally provided with specialized connectors for receiving power from stationary solar panels, and there is also a built-in MPPT charge controller (Maximum Power Point Tracking).

Input port XT60

Power connector with two round connectors, used to replenish energy reserves in the battery cells of the charging station. For the most part, the input port of the XT60 is for charging the device from solar panels using the appropriate cable.

Battery type

Li-Ion. The key advantage of lithium-ion batteries is their high capacity with small dimensions and weight. Also, Li-Ion batteries are not subject to memory effect and can charge quite quickly. Of course, this option is not without its drawbacks - first of all, it is sensitivity to low or elevated temperatures, and if overloaded, the lithium-ion battery can catch fire or even explode. However, thanks to the use of built-in controllers, the likelihood of such “accidents” is extremely low and, in general, the advantages of this technology significantly outweigh the disadvantages.

Li-Pol. An improved version of lithium-ion technology (see the corresponding paragraph): the liquid electrolyte in Li-Pol batteries is replaced with a solid polymer. At the same high capacity, the batteries have become more compact, there is practically no “memory effect” in them, and the likelihood of fires and explosions in the event of critical violations of operating conditions is minimized. The downside of these improvements was increased cost and increased sensitivity to frost. However, most often these shortcomings are not significant.

LiFePO4. Lithium iron phosphate batteries are a modification of lithium ion batteries (see corresponding paragraph) designed to eliminate some of the shortcomings of the original technology. LiFePO4 batteries are characterized by a...large number of charge/discharge cycles, chemical and thermal stability, low temperature tolerance, short charging time (including high currents) and safety in operation. The likelihood of an “explosion” of a LiFePO4 battery when overloaded is reduced to almost zero, and in general, such batteries cope with high peak loads without problems and maintain the operating voltage almost until discharge.

Li-Ion NMC. A type of lithium rechargeable battery using a complex alloy in the manufacture of the cathode. It contains nickel, manganese and cadmium. This “recipe” allows you to increase the power of a power source based on Li-Ion NMC elements. Batteries of this type have a high specific capacity and a stable discharge voltage, provide a long operating time of the charging station with high performance, are characterized by a complete absence of “memory effect”, maintain functionality over a wide temperature range and are fireproof.

— VRLA. Acid batteries with a regulating safety valve to release excess gas. The abbreviation VRLA stands for Valve Regulated Lead Acid. Batteries of this type have a sealed, non-separable design and come in two types: AGM VRLA (the battery plates are equipped with a layer of fiberglass absorbent) and GEL VRLA (with a gel electrolyte in a jelly-like state). Batteries with a control valve are resistant to deep discharges, do not require topping up with distillate throughout their entire service life, and do not emit hydrogen or oxygen.

- Semi-solid State. An advanced type of lithium-ion battery (see above), which combines some of the characteristics of liquid and solid batteries. It uses an electrolyte that is in a semi-soft or gel-like state, making the batteries more resistant to leakage than traditional wet batteries. Semi-solid state technology allows for a significant increase in the energy density of cells. As a result, it is possible to make compact batteries with high energy intensity.

Battery capacity

Nominal battery capacity, in fact - the amount of energy that is supposed to be stored. The larger it is, the longer the battery life of the charging station will be, all other things being equal. On the other hand, this parameter also affects the dimensions, weight and price of the battery, despite the fact that an energy-intensive battery is not always required. By the indicator of capacity in watt-hours, you can compare batteries with each other.
XO PSA-700 often compared
EcoFlow RIVER Max often compared