USA
Catalog   /   Home & Renovation   /   Autonomous Power Supply   /   Inverters and controllers

Comparison Deye SUN-8K-SG01LP1-EU vs Deye SUN-5K-SG03LP1-EU

Add to comparison
Deye SUN-8K-SG01LP1-EU
Deye SUN-5K-SG03LP1-EU
Deye SUN-8K-SG01LP1-EUDeye SUN-5K-SG03LP1-EU
Outdated ProductOutdated Product
TOP sellers
Device typehybrid inverterhybrid inverter
Network type1 phase (230 V)1 phase (230 V)
Maximum efficiency97.6 %97.6 %
Euro efficiency97 %96.5 %
AC input/output
Rated power8800 VA5500 VA
Rated power8000 W5000 W
Peak power16000 W10000 W
Rated AC current34.8 A21.7 A
Maximum AC power38.3 А23.9 А
Output waveformpure sine wavepure sine wave
Batteries and DC charging
Connection voltage48 V48 V
Number of battery inputs11
Maximum charge current190 А120 А
Solar PV panels
Max. power10.4 kW6.5 kW
Operating voltage PV150 – 425 V370 V
Short circuit current
88 А /44 A MPP1, 44 A MPP2/
34 А /17 A MPP1, 17 A MPP2/
MPPT controller(s)22
Number of strings21
Features and control
Control interfaces
RS485
RS485
Protection
Reverse polarity protection
Short circuit protection
↑ or ↓ battery voltage protection
Overload protection
Overheat protection
Reverse polarity protection
Short circuit protection
↑ or ↓ battery voltage protection
Overload protection
Overheat protection
General
Displayis absentis absent
Coolingactive (fans)active (fans)
Noise level30 dB30 dB
Casing protection classIP65IP65
Operating temperature-40 °C ~ +60 °C-40 °C ~ +60 °C
Dimensions420x670x233 mm330x580x232 mm
Weight32 kg20.5 kg
Added to E-Catalogmay 2023may 2023

Rated power

The rated output power of the inverter, expressed in volt-amperes (VA). Essentially, this value is equivalent to power in watts (W).

This parameter refers to the power that the device can continuously deliver to consumers. When choosing based on this parameter, ensure that the rated power of the inverter exceeds the expected load power by approximately 15-20%. Additionally, keep in mind that some electrical appliances (particularly those with electric motors, such as vacuum cleaners, refrigerators, etc.) consume significantly more energy at startup than during regular operation. For such loads, it's important to check the peak power of the inverter (see the relevant paragraph) — it should be higher than the starting power of the load.

Rated power

The rated output power of the inverter, expressed in watts (W).

This parameter means the power that the device can provide to consumers for an unlimited time. It is necessary to choose according to this indicator so that the rated power of the inverter covers the power consumption of the expected load by approximately 15-20%. It is also worth considering that some electrical appliances (in particular, units with electric motors - vacuum cleaners, refrigerators, etc.) consume significantly more energy when starting up than after entering the mode. For such a load, it is also necessary to clarify the peak power of the inverter (see the corresponding paragraph) - it should be higher than the starting power of the load.

Peak power

The highest total output power in watts (W) that the inverter can deliver to a load for a relatively short period of time, on the order of 2 to 3 seconds. As a rule, this power is 30 - 50% more than the rated power (see above). The peak load value can be useful when calculating how the inverter works together with appliances that consume a lot of energy at start-up (vacuum cleaners, borehole pumps, power tools, etc.). The rule here is simple - the peak power of the inverter must not be lower than the starting power of the load.

Maximum AC power

The maximum current in amperes (A) that the inverter, when operating, is capable of outputting without overloads or failures.

Maximum charge current

The maximum amount of direct current in amperes that the inverter can convert. If the solar panel produces a current exceeding this value, the inverter simply does not use it. This is often justified when connecting an inverter to high-power solar panels - the maximum input current of the inverter is reduced to acceptable values so that moderate-sized wires can be used to transmit energy.

Max. power

The maximum allowable input power from solar panels, expressed in kilowatts (kW). Let us remember that 1 kW contains 1000 W.

When selecting an inverter based on this indicator, they are based on the total power of the solar panels involved in generating electricity. Moreover, it often makes sense to select models with an inverter input power slightly less than the maximum power of solar panels - for example, if they are shaded part of the time or for other reasons do not receive enough sunlight during the day. The power of the solar battery should not exceed the power of the inverter by more than 30%. However, for some inverters the excess can be only 10%, while for others it can be up to 100%. It is better to clarify this point in advance.

Operating voltage PV

The operating range of the inverter is usually located between the starting voltage and the maximum voltage. This interval is indicated in volts.

Short circuit current

The maximum solar panel short circuit current that the inverter can accept without the risk of breakdown or emergency shutdown. The parameter is usually indicated in amperes.

Number of strings

Strings in solar energy are chains of panels connected in series. With this connection method, the voltage of the solar panels is summed up, and the current remains constant, which allows you to significantly increase the power generation capacity while maintaining a fairly low current and without the need to use large-section wires.

Specifically, this paragraph indicates the maximum number of strings that can be connected to the inverter for solar panels.
Deye SUN-8K-SG01LP1-EU often compared