Max. performance2700 L/h
2700 L/h /maximum/
Max. head65 m
86 m /maximum/
Specs
Operating principlecentrifugalcentrifugal
Max. immersion depth60 m60 m
pH value6.5 – 8.56.5 – 8.5
Suction systemsingle stage
multistage /20 steps/
Oulet size1"1"
Max. liquid T35 °С35 °С
Motor
Power consumption550 W550 W
Mains voltage230 V230 V
Power cable length1.5 m1.5 m
General specs
Overload protection
Country of originUkraine
Impeller materialstainless steeltechnopolymer
Dimensions72x908 mm75х1058 mm
Weight8.31 kg
Added to E-Catalogapril 2022april 2015

Max. head

The maximum head is the maximum height to which the pump can raise water during operation (the highest height of the water column that it can support). This parameter describes the pressure created during operation, but since the operation of well pumps is directly related mainly to lifting liquid to a great height, it is easier to use head data in metres than pressure data. However, if necessary, one can be easily translated into another — 10 m of pressure corresponding to a pressure of 1 bar.

When choosing a pump for this parameter, it is not necessary to chase a large pressure, but it is necessary to take into account several factors.

The first of these is the actual height to which the water must be raised; it can be determined by adding the immersion depth of the pump and the height of the highest draw-off point above the ground. The immersion depth is displayed taking into account the so-called dynamic water level in the well — i.e. distance from the surface of the earth to the water surface during continuous operation of the pump (this indicator is greater than the static level, since when the water is pumped out, its level decreases). The dynamic level is usually indicated in the well passport; the pump should be at least a metre deep underwater, plus a margin of 2 – 3 m should be taken as an adjustment for seasonal level fluctuations. Accordingly, for a well with a dynamic depth of 40 m, supplying a house with...an upper draw-off point of 6 m above the ground, the total height difference will be at least 40 + 6 + 4 = 50 m.

The second point is the hydraulic resistance of the system. Even with horizontal pipes, pressure is required to move fluid through them; usually, when calculating, it is assumed that for every 10 m of the pipeline, 0.1 bar, or 1 m of head, is required. For a water supply system inside an average house, resistance losses are about 5 m of head (0.5 bar). Accordingly, if in our example the house is located 10 m from the well, then the margin to overcome the resistance should be at least 1 + 5 = 6 m of head.

And the third point is the pressure at the points of water intake because the pump must not only “push” the water to the tap, but also provide pressure at the outlet. Here, the optimal values may be different depending on the situation. For example, let's take at least 1 atm (1 bar), which corresponds to 10 m of pressure.

Thus, in our example, the pump head must be at least 50 m (height difference) + 6 m (resistance) + 10 m (outlet head) = 66 m. Of course, this is a calculation for the most general case; in special situations, the formulas may differ, so it makes sense to refer to special sources for them.

Suction system

— Single stage. Suction system with one impeller or similar element. Although this design loses to multistage in terms of efficiency and power, at the same time, its characteristics are quite enough for most entry-level and mid-level pumps; at the same time, single-stage units are simpler and cheaper.

— Multistage. This suction system consists of several impellers (or other similar parts that directly provide suction). Such pumps are noticeably superior to single-stage ones, they provide powerful pressure and are less sensitive to impurities. At the same time, multistage systems are quite expensive.

Overload protection

A safety system in case of an overload of a deep well pump when its engine is running beyond its capacity. It can lead to engine failure or even fire. Overloading is usually prevented by thermal current relays introduced into the circuit of pumping equipment.

Country of origin

In this case, the country of origin refers to the country from which the product brand originates. A brand, in turn, is a general designation by which the products of a particular company are known in the market. The country of its origin does not always coincide with the actual place of production of the device: to reduce the cost of production, many modern companies transfer it to other countries. It is quite normal for products, for example, of an American or German brand, to be made in Taiwan or Turkey. Contrary to popular belief, this in itself does not lead to a decrease in the quality of the goods — it all depends on how carefully the brand owner controls the production. And many companies, especially large and "famous", monitor the quality very zealously — after all, their reputation depends on it. However, the range on the market is not so great. In addition to East European pumps, there are models from Italy and China.

Impeller material

The material from which the pump impeller is made.

A wide variety of materials are used in modern well pumps. However, the manufacturer, usually, chooses the option so that the strength, reliability, resistance to pollution and other key features of the wheel correspond to the required characteristics of the pump and its level as a whole. In addition, the same material may have several varieties that differ markedly in characteristics; this is especially true for technopolymers and thermoplastics, but most metallic materials such as stainless steel or brass also come in several grades. All this means that when choosing a pump, it makes sense to look first of all at performance characteristics, price category, reviews and other practically significant information, and the material of the impeller is of secondary importance.
Aquatica 77710 often compared