USA
Catalog   /   Tools & Gardening   /   Machines & Equipment   /   Generators

Comparison Vitals Master IG 1800bs vs Konner&Sohnen Basic KSB 21i S

Add to comparison
Vitals Master IG 1800bs
Konner&Sohnen Basic KSB 21i S
Vitals Master IG 1800bsKonner&Sohnen Basic KSB 21i S
Outdated ProductOutdated Product
TOP sellers
Main
Inverter alternator. Light weight. Output 12 V.
Fuelpetrolpetrol
Output voltage230 B230 B
Rated power1.8 kW1.8 kW
Max. power2 kW2 kW
Alternatorinverterinverter
Alternator windingcoppercopper
Engine
ICE type4-stroke4-stroke
Motor typeKSB 100i
Engine size79 cm³80 cm³
Power3.5 hp2.9 hp
Launch typemanualmanual
Fuel consumption
0.73 L/h /at 50% load/
Fuel consumption360 g/kW·h
Fuel tank volume4 L4 L
Fuel level indicator
Continuous operation time
5.5 h /at 50% load/
Motor coolingairair
Connection
Number of sockets (230/400 V)12
Sockets 230 V16 A x116 A x2
USB charging port
Output 12 Vsocket
Features
Functions
display
hour metre
voltmeter
parallel connection
 
 
 
 
General
Sound insulation cover
Protection levelIP 23
Noise level65 dB
93 dB /LWA; 59 dB — at 7 m (LpA)/
Sound level (7 m)52 dB
Dimensions540x325x490 mm535x335x480 mm
Weight21 kg20 kg
Added to E-Catalogaugust 2023february 2021

Motor type

Model name of the engine installed in the generator. Knowing this name, you can, if necessary, find detailed data on the engine and clarify how it meets your requirements. In addition, model data may be needed for some specific tasks, including maintenance and repair.

Note that modern generators are often equipped with branded engines from famous manufacturers: Honda, John Deere, Mitsubishi, Volvo, etc. Such engines are more expensive than similar units from little-known brands, but this is offset by higher quality and/or solid warranty conditions , and in many cases, the ease of finding spare parts and additional documentation (such as manuals for special maintenance and minor repairs).

Engine size

The working volume of the engine in a gasoline or diesel generator (see "Fuel"). Theoretically, more volume usually means more power, but in fact, everything is not so clear. Firstly, the specific power strongly depends on the type of fuel, and in gasoline units, also on the type of internal combustion engine (see above). Secondly, similar engines of the same power can have different volumes, and there is a practical point here: with the same power, a larger engine consumes more fuel, but by itself it can cost less.

Power

The operating power of the engine installed in the generator. Traditionally stated in horsepower; 1 HP approximately equal to 735 watts.

First of all, the rated power of the generator directly depends on this indicator (see above): in principle, it cannot be higher than the engine power, moreover, part of the engine power is spent on heat, friction and other losses. And the smaller the difference between these capacities, the higher the efficiency of the generator and the more economical it is. However high efficiency affects the cost, but this difference can pay off with regular use due to fuel savings.

Fuel consumption

Fuel consumption of a gasoline or diesel generator, and for combined models — when using gasoline (see "Fuel").

A more powerful engine inevitably means more fuel consumption; however, models with the same engine power may differ in this indicator. In such cases, it is worth considering that a model with a lower flow rate usually costs more, but this difference can quickly pay off, especially with regular use. In addition, knowing the fuel consumption and tank volume, you can determine how long one refueling will last; at the same time, in inverter models at partial load, the actual operating time may be noticeably higher than the theoretical one, see "Alternator" for details.

Fuel consumption

Specific fuel consumption in grams consumed by the generator to generate 1 kW of electricity for 1 hour. Knowing this indicator, it is possible to calculate the approximate fuel consumption in liters, taking into account the power of the connected load and the expected duration of the unit. To do this, you need to multiply the specific consumption in g / kWh by the power of the generator engine and divide the result by the density of the fuel used (approximately 830-860 kg / m³ for diesel and 710-760 kg / m³ for gasoline).

Fuel level indicator

A pointer that allows you to monitor the remaining fuel in the generator tank. The simplest such indicators work only with a critical decrease in the level of fuel, warning of the need for refueling; more advanced ones constantly display the remainder. However, anyway, this feature makes it easier to keep track of the fuel supply and reduces the risk of a generator shutdown due to a forgotten refueling.

Continuous operation time

The time during which the generator is guaranteed to operate without interruption.

This parameter is indicated exclusively for liquid fuel models with a built-in tank, and according to the simplest formula: tank capacity divided by fuel consumption. However, in some models, data may be provided for a certain load level (which is specified in the notes); at a higher or lower load, the operating time will be shorter or longer, respectively. As for specific numbers, in most modern generators the operating time is up to 8 hours - this is quite enough for backup power and occasional use. More reputable models are capable of working for 8 – 12 hours, and an indicator of 13 hours and above is typical mainly for professional solutions.

We also note that, theoretically, many generators can be refueled without shutting down, but in practice it is better to take breaks and not exceed the stated time of continuous operation - this will avoid overheating and increased wear.

Number of sockets (230/400 V)

The total number of 230 and/or 400 V outlets provided in the generator design.

This number corresponds to the number of devices that can be simultaneously connected to the generator without the use of splitters, extension cords, etc. Moreover, if we are talking about a three-phase model (see “Output voltage”) with different types of sockets, it would not hurt to specify the number of both separately, since the set may be different in different models. For example, a unit for which 3 sockets are declared may have 1 three-phase connector and 2 single-phase, or 2 three-phase and 1 single-phase. In general, the most limited modern generators have only 1 outlet, although models with 2 are more common; and in the most powerful models this number can be 4 or higher.

Let us also recall that the possibilities for connecting various devices are limited not only by the number of sockets, but also by the rated power of the generator (for more details, see above).

Sockets 230 V

The number of 230 V sockets provided in the design of the generator, as well as the type of connectors used in such sockets.

The type of connector in this case is indicated by the maximum current that is allowed for the outlet — for example, "2 pcs at 16 A". The most popular options for 220-volt outlets are 16 A, 32 A and 63 A. We emphasize that the amperes in this designation are not the actual current that the generator can produce, but the outlet's own limitation; the actual value of the current strength is usually noticeably lower. Simply put, if, for example, the generator has a 32 A socket, the output current on it will not reach 32 A; and the specific number of amperes will depend on the rated and maximum power of the unit (see above). So, if for our example we take a rated power of 5 kW and a maximum of 6 kW, then such a generator can deliver less than 5 kW / 230 V = 22.7 A nominally and 6 kW / 230 V = 27 to a 230 V socket, 3 And at the peak. And if the power has to be divided between several outlets, then it, accordingly, will be even less.

As for specific types of connectors, the higher the current allowed for the outlet, the higher the requirements for its reliability and quality of protection. Thus, usually, smaller power plugs can be connected to higher power sockets (directly or through an adapter), but not vice versa. And if there are several sockets, by their type it is pos...sible to estimate with a certain certainty the distribution of the entire power of the generator between them: between two identical sockets, this power is usually divided equally, and more power is allocated to the socket for a larger number of amperes. However, specific details on this matter should be clarified in each case separately; also consider 400 V sockets, if available (see below).
Vitals Master IG 1800bs often compared
Konner&Sohnen Basic KSB 21i S often compared