Suitable for full time work. Intelligent voltage stabilization system AVR. Preheating. Economical fuel consumption. Information LED-screen.
Fueldieseldiesel
Output voltage230 B230 B
Rated power5 kW5 kW
Max. power5.5 kW5.5 kW
Alternatorsynchronoussynchronous
Engine
ICE type4-stroke4-stroke
Motor typeKS 440HDKS 450HD
Engine size418 cm³418 cm³
Power12 hp12 hp
Launch typeelectric starter (key)electric starter (key)
Fuel consumption
1.15 L/h /at 50% load/
Fuel tank volume15 L15 L
Fuel level indicator
Continuous operation time
13 h /at 50% load/
Motor coolingairair
Connection
Number of sockets (230/400 V)2
Sockets 230 V16 A x1, 32 A x1
Output 12 Vterminalsterminals
Features
Functions
automatic voltage regulator (AVR)
display
hour metre
voltmeter
automatic voltage regulator (AVR)
display
hour metre
voltmeter
General
Protection levelIP 23
Noise level96 dB96 dB
Dimensions730x495x630 mm765x530x630 mm
Weight107 kg107 kg
Added to E-Catalogmarch 2020september 2017

Motor type

Model name of the engine installed in the generator. Knowing this name, you can, if necessary, find detailed data on the engine and clarify how it meets your requirements. In addition, model data may be needed for some specific tasks, including maintenance and repair.

Note that modern generators are often equipped with branded engines from famous manufacturers: Honda, John Deere, Mitsubishi, Volvo, etc. Such engines are more expensive than similar units from little-known brands, but this is offset by higher quality and/or solid warranty conditions , and in many cases, the ease of finding spare parts and additional documentation (such as manuals for special maintenance and minor repairs).

Fuel consumption

Fuel consumption of a gasoline or diesel generator, and for combined models — when using gasoline (see "Fuel").

A more powerful engine inevitably means more fuel consumption; however, models with the same engine power may differ in this indicator. In such cases, it is worth considering that a model with a lower flow rate usually costs more, but this difference can quickly pay off, especially with regular use. In addition, knowing the fuel consumption and tank volume, you can determine how long one refueling will last; at the same time, in inverter models at partial load, the actual operating time may be noticeably higher than the theoretical one, see "Alternator" for details.

Continuous operation time

The time during which the generator is guaranteed to operate without interruption.

This parameter is indicated exclusively for liquid fuel models with a built-in tank, and according to the simplest formula: tank capacity divided by fuel consumption. However, in some models, data may be provided for a certain load level (which is specified in the notes); at a higher or lower load, the operating time will be shorter or longer, respectively. As for specific numbers, in most modern generators the operating time is up to 8 hours - this is quite enough for backup power and occasional use. More reputable models are capable of working for 8 – 12 hours, and an indicator of 13 hours and above is typical mainly for professional solutions.

We also note that, theoretically, many generators can be refueled without shutting down, but in practice it is better to take breaks and not exceed the stated time of continuous operation - this will avoid overheating and increased wear.

Number of sockets (230/400 V)

The total number of 230 and/or 400 V outlets provided in the generator design.

This number corresponds to the number of devices that can be simultaneously connected to the generator without the use of splitters, extension cords, etc. Moreover, if we are talking about a three-phase model (see “Output voltage”) with different types of sockets, it would not hurt to specify the number of both separately, since the set may be different in different models. For example, a unit for which 3 sockets are declared may have 1 three-phase connector and 2 single-phase, or 2 three-phase and 1 single-phase. In general, the most limited modern generators have only 1 outlet, although models with 2 are more common; and in the most powerful models this number can be 4 or higher.

Let us also recall that the possibilities for connecting various devices are limited not only by the number of sockets, but also by the rated power of the generator (for more details, see above).

Sockets 230 V

The number of 230 V sockets provided in the design of the generator, as well as the type of connectors used in such sockets.

The type of connector in this case is indicated by the maximum current that is allowed for the outlet — for example, "2 pcs at 16 A". The most popular options for 220-volt outlets are 16 A, 32 A and 63 A. We emphasize that the amperes in this designation are not the actual current that the generator can produce, but the outlet's own limitation; the actual value of the current strength is usually noticeably lower. Simply put, if, for example, the generator has a 32 A socket, the output current on it will not reach 32 A; and the specific number of amperes will depend on the rated and maximum power of the unit (see above). So, if for our example we take a rated power of 5 kW and a maximum of 6 kW, then such a generator can deliver less than 5 kW / 230 V = 22.7 A nominally and 6 kW / 230 V = 27 to a 230 V socket, 3 And at the peak. And if the power has to be divided between several outlets, then it, accordingly, will be even less.

As for specific types of connectors, the higher the current allowed for the outlet, the higher the requirements for its reliability and quality of protection. Thus, usually, smaller power plugs can be connected to higher power sockets (directly or through an adapter), but not vice versa. And if there are several sockets, by their type it is pos...sible to estimate with a certain certainty the distribution of the entire power of the generator between them: between two identical sockets, this power is usually divided equally, and more power is allocated to the socket for a larger number of amperes. However, specific details on this matter should be clarified in each case separately; also consider 400 V sockets, if available (see below).

Protection level

The level of protection provided by the generator housing — namely, the degree of protection of the “hardware” from dust, moisture and foreign objects. It is designated by the IP standard with two numbers, one of which corresponds to protection against solid objects and dust, the second — from moisture, for example, IP24.

According to the level of dust protection (first digit) in modern generators, the following values \u200b\u200bare found:

2 — protection against objects with a diameter of more than 12.5 mm (fingers, etc.);
3 — from objects larger than 2.5 mm (most instruments);
4 — from objects more than 1 mm (almost all tools, most wires);
5 — dustproof (full protection against contact; dust can penetrate inside, but does not affect the operation of the device).

Water protection levels can be as follows:

1 — protection against vertically falling drops of water;
2 — from water drops with a deviation of up to 15 ° from the vertical axis of the device (rain);
3 — from water drops with a deviation of up to 60 ° from the vertical axis of the device (rain with wind);
4 — against splashes from any direction (rain with strong wind);


In general, for indoor use, this indicator does not play a key role, but on the street and in similar conditions (for example, at a construction site), you should make sure that the selected generator is sufficiently protected — or else take additional protection measures.
Konner&Sohnen Heavy Duty KS 6102HDE often compared
Konner&Sohnen Heavy Duty KS 6100HDE often compared