USA
Catalog   /   Home & Renovation   /   Electrical Equipment   /   Surge Protectors & Extension Leads

Comparison Belkin SRB001vf2M vs Belkin SRB001ca2M

Add to comparison
Belkin SRB001vf2M
Belkin SRB001ca2M
Belkin SRB001vf2MBelkin SRB001ca2M
Compare prices 1Expecting restock
TOP sellers
Product typesurge protectorextension
Specs
Cable length2 m2 m
Max. load16 A
Max. energy absorption525 J525 J
Operation indicator
Power switchgeneralgeneral
Connection
Plug typeon camera flasheson camera flashes
Grounded sockets (type F)4
Grounded outlets (Type E)4 pcs
USB A11
USB C11
Protection
voltage drop
 
Design features
Safety socket cover
Socket plugsangledangled
Color
Added to E-Catalogseptember 2023september 2023

Product type

The general features of the design and application of the network filter depend on the type.

Extension lead. Traditional extension cords designed to bring power to devices located far from outlets, as well as to increase the number of sockets themselves. They do not have built-in filters and provide almost no protection. On the other hand, such devices are extremely simple and inexpensive.

Cable reel. Extension cords in which the wire is wound on a spool. They are significantly longer than models without coils; in addition, the user can adjust the length of the wire at his discretion. On the other hand, the weight and dimensions of such devices are also quite significant. As a result, extension cords on a reel are not well suited for home use, but may be indispensable for some specific tasks. For example, using such a device, you can stretch power through the yard of a private house, for work in a garage or a barn.

H-frame extension lead. Extension cords in which the wire is wound around the frame — a special holder that resembles a double-sided horn. The design of the frame itself allows you to conveniently unwind and wind the power cord, while the wire is not subjected to twisting into knots and tangles. The extension cord on the frame usually has only one socket for connecting an electric current consumer.

— Roulette ex...tension lead. A kind of extension cord with a round body, in which the cord is wound in the manner as it is implemented in construction roulettes. In its upper part there are sockets (their number and type may differ), and on the reverse side there is a handle for returning the cord to the case. There is no automatic winding of the cord on the coil inside the case.

Surge protected adapter. The simplest type of network filters are compact devices that are attached directly to the outlet. The possibilities of such devices are extremely simple: other connectors, in addition to ordinary sockets, are extremely rare in them, and the sockets themselves are usually provided with less than one (although exceptions are possible). On the other hand, small size in some situations can be an important advantage. In addition, such a filter can be constantly worn on the plug of the device with which it is used.

— Surge protector. Devices that combine the functions of a surge protector and an extension cord: allow you to connect electrical appliances to the network that are remote from outlets, while smoothing out the interference that occurs on the network. In addition, most models have several outlets, which allows you to connect several devices to one such filter at once. Note that models with 3-5 outlets are very popular as a means of connecting desktop PCs to a network: they allow you to power both the system unit and peripherals (monitor, speakers, printer, etc.) and additional devices like a table lamp from one outlet .

— Surge protector reel. Network filters equipped with a wire reel. According to the features of the application, they are completely similar to the extension cords on the reel described above, adjusted for the fact that in this case the device not only works as a remote outlet, but also protects the load from interference in the network.

Max. load

The maximum current that the surge protector can pass through itself for an unlimited time without the risk of overheating, breakdowns and other troubles.

This parameter is directly related to the maximum power of the filter (see above): power is the current multiplied by the voltage. Thus, for example, for a standard 230 V model with a maximum power of 2200 W, the maximum load will be 10 A. Note that the characteristics of modern filters may not correspond to such calculations — for example, the same 10 A can be claimed for a 2500 W model . However, this is not something extraordinary: the difference in figures may be due to active and reactive power (see "Maximum power"), the characteristics of single-phase filters (without 400 V sockets, see above) can be given both for 230 V, so for 230 V and even 240 V, figures may be rounded for readability, etc.

Anyway, the practical value of the maximum load is the same as the maximum power: it should not be less than the current supplied to the connected electrical appliances (otherwise the protection may trip, or even break). And they use this parameter, along with the maximum power, because in some cases it is easier to evaluate the characteristics of the load (and filter requirements) in terms of current consumption, and not in terms of power.

Grounded sockets (type F)

The number of sockets with type F grounding, provided in the design of the mains filter.

In this case, we are talking about full-size European type F sockets with metal ground clamps on both sides at the edges of the socket. The "socket" in this case means a CEE 7/4 ("Schuko") standard plug. Grounding is required for the safe operation of some types of electrical appliances, in particular, washing machines and other machines that work with water, refrigerators, computers, audio equipment, etc. A detailed list can be found in the reference literature. If you plan to connect such devices through the filter, this filter must have sockets with grounding.

Grounded outlets (Type E)

The number of sockets with type E grounding, provided in the design of the mains filter.

French Type E sockets use a two-hole pattern for the supply of electrical current and an integrated earth pin just above the center plane of the socket. Plugs for them are made with a characteristic hole for a grounding contact.

Protection

Short circuit protection. Short circuit (short circuit) protection system — situations when the impedance in the circuit drops sharply, for example, due to a metal object falling between the socket contacts. It reacts to a sharp increase in current and opens the circuit, allowing you to avoid damage and fire equipment.

Voltage drops protection. Protection against power surges in the network. A filter with this function is able to completely cut off power that exceeds the allowable rate set by the manufacturer, protecting the load from damage. Note that the surge protector is not able to replace a full-fledged stabilizer or voltage relay; however, in more or less high-quality networks that are not subject to strong fluctuations, a filter is quite enough.

Overload protection. In this case, overload means a situation when the load power exceeds the values \u200b\u200ballowed for a given network filter. This situation is similar to the short circuit described above — high currents go through the filter; however, overload has its own specifics, so protection against it can be provided as a separate system. However, the principle of operation of such systems is classic: when the permissible power is exceeded, it turns off the power, preventing breakdowns and fires.

Varistor protection. A kind of protectio...n against short-term power surges in the network, built on varistors — variable impedance resistors. The impedance of such a resistor under normal conditions is in the millions of ohms, but it drops sharply if the input voltage increases above a certain value. Due to this, in normal mode, the protection practically does not affect the circuit, and with a high-voltage pulse, excess energy “merges” through the varistor and dissipates in the form of heat. The ability of varistors to absorb energy is not infinite, therefore, to protect against overheating, the design usually provides for a temperature sensor with an automatic switch.