Comparison Bizon FS Optima Termo 12 12 kW vs Brest Ultra 12 12 kW

Add to comparison
Bizon FS Optima Termo 12 12 kW
Brest Ultra 12 12 kW
Bizon FS Optima Termo 12 12 kWBrest Ultra 12 12 kW
Outdated ProductExpecting restock
TOP sellers
Energy sourcesolid fuelsolid fuel
Installationfloorfloor
Typesingle-circuit (heating only)single-circuit (heating only)
Heating area96 m²96 m²
Long burning
Technical specs
Heat output12 kW12 kW
Power supplyautonomous (no electricity)autonomous (no electricity)
Coolant min. T60 °С
Coolant max. T90 °С90 °С
Heating circuit max. pressure2 bar2 bar
Consumer specs
Circulation pump
Boiler specs
Efficiency85 %81 %
Combustion chamberopen (atmospheric)open (atmospheric)
Flue diameter159 mm159 mm
Connections
Central heating flow1 1/2"
Central heating return1 1/2"
More specs
Firebox size
100 dm³
 
Dimensions (HxWxD)1080x460x840 mm780x460x730 mm
Weight175 kg146 kg
Added to E-Catalogjune 2023may 2023

Coolant min. T

The minimum operating temperature of the heat medium in the boiler system when operating in heating mode.

Efficiency

The efficiency of the boiler.

For electric models (see "Energy source"), this parameter is calculated as the ratio of net power to consumed; in such models, indicators of 98 – 99% are not uncommon. For other boilers, the efficiency is the ratio of the amount of heat directly transferred to the water to the total heat amount released during combustion. In such devices, the efficiency is lower than in electric ones; for them, a parameter of more than 90% is considered good. An exception is gas condensing boilers (see the relevant paragraph), where the efficiency can even be higher than 100%. There is no violation of the laws of physics here. It is a kind of advertising trick: when calculating the efficiency, an inaccurate method is used that does not take into account the energy spent on the formation of water vapour. Nevertheless, formally everything is correct: the boiler gives out more thermal energy to the water than is released during the combustion of fuel since condensation energy is added to the combustion energy.

Central heating flow

The diameter of the pipe for connecting the pipe through which the heated water enters the heating system from the boiler.

Diameters are indicated in inches. In some cases, it is allowed to connect a pipe of a different diameter through an adapter, but the best option is still a match in size. Among which models stand out for 3/4", 1", 1 1/4" and 1 1/2".

Central heating return

The diameter of the pipe for connecting the pipe through which the cooled water returns from the heating system to the boiler.

Diameters are indicated in inches. In some cases, it is allowed to connect a pipe of a different diameter through an adapter, but the best option is still a match in size.

Firebox size

The size of the furnace is described by two parameters:

1. directly by the dimensions, due to which it is possible to determine the appropriate size firewood for use with the boiler;

2. volume, which characterizes the amount of fuel used in the furnace.