Comparison Altep CLASSIC 12 12 kW vs Kronas Eko 12 12 kW

Add to comparison
Altep CLASSIC 12 12 kW
Kronas Eko 12 12 kW
Altep CLASSIC 12 12 kWKronas Eko 12 12 kW
Outdated ProductOutdated Product
TOP sellers
Energy sourcesolid fuelsolid fuel
Installationfloorfloor
Typesingle-circuit (heating only)single-circuit (heating only)
Heating area96 m²96 m²
Long burning
Technical specs
Heat output12 kW12 kW
Power supplyautonomous (no electricity)autonomous (no electricity)
Coolant min. T58 °С60 °С
Coolant max. T85 °С90 °С
Heating circuit max. pressure1.5 bar2 bar
Consumer specs
Circulation pump
Boiler specs
Efficiency86 %85 %
Combustion chamberopen (atmospheric)open (atmospheric)
Flue diameter160 mm159 mm
Heat exchangercast iron
Connections
Central heating flow2"1 1/2"
Central heating return2"1 1/2"
Safety
Safety systems
 
water overheating
More specs
Firebox size
 
 
350x295 mm
46 dm³
Dimensions (HxWxD)1185x650x860 mm920x645x890 mm
Weight255 kg110 kg
Added to E-Catalogoctober 2018december 2017

Coolant min. T

The minimum operating temperature of the heat medium in the boiler system when operating in heating mode.

Coolant max. T

The maximum operating temperature of the heat medium in the boiler system when operating in heating mode.

Heating circuit max. pressure

The maximum pressure in the heating circuit of the boiler, at which it remains operational, and there is no risk of physical damage to the structure. For a heating system, the maximum pressure is usually about 3 bar, and for a domestic hot water circuit up to 10 bar. When the maximum pressure is exceeded, a safety valve is activated, and part of the water is discharged from the system until a normal pressure level is reached.

Efficiency

The efficiency of the boiler.

For electric models (see "Energy source"), this parameter is calculated as the ratio of net power to consumed; in such models, indicators of 98 – 99% are not uncommon. For other boilers, the efficiency is the ratio of the amount of heat directly transferred to the water to the total heat amount released during combustion. In such devices, the efficiency is lower than in electric ones; for them, a parameter of more than 90% is considered good. An exception is gas condensing boilers (see the relevant paragraph), where the efficiency can even be higher than 100%. There is no violation of the laws of physics here. It is a kind of advertising trick: when calculating the efficiency, an inaccurate method is used that does not take into account the energy spent on the formation of water vapour. Nevertheless, formally everything is correct: the boiler gives out more thermal energy to the water than is released during the combustion of fuel since condensation energy is added to the combustion energy.

Flue diameter

The diameter of the pipe through which combustion products are discharged from the combustion chamber.

In boilers with a closed combustion chamber often used the coaxial flue, consisting of two pipes nested one inside the other. At the same time, products of combustion are discharged from the combustion chamber through the inner pipe, and the air is supplied through the gap between the inner and outer ones. For such flues, the diameter is usually shown in the form of two numbers — the diameter of the inner and outer pipes, respectively. The most popular values are 60/100, 80/80 and 80/125. Non-coaxial flues can be 100, 110, 125, 130, 140, 150, 160, 180 and 200 mm.

Heat exchanger

The material of the primary heat exchanger, in which thermal energy from hot combustion products is transferred to the heat medium. The efficiency of the boiler, the heating rate and the service life of the unit directly depend on the material of the heat exchanger.

Copper. Copper is a material with the best heat dissipation specs and high corrosion resistance. It heats up quickly, which allows you to save energy during the operation of the heating boiler, has a low roughness coefficient, and has a long service life. The only drawback of this metal is its high cost. Copper heat exchangers are installed in heavy mid-range and premium grade equipment.

Aluminium. Aluminium as a heat exchanger material is characterized by excellent thermal conductivity and long service life. Moreover, it is cheaper than copper. To reduce the cost of production in copper heat exchangers, they try to reduce the wall thickness. You don't need to do this with aluminium.

Cast iron. Boilers with a cast-iron heat exchanger heat up for a long time and cool down slowly, retaining heat for a long time after heating stops. Cast iron is also notable for its high heat capacity and low susceptibility to corrosion. The service life of a cast iron unit can be 30 or 50 years. The reverse side of the coin is the huge weight and size of hea...ting equipment, which is why boilers with cast-iron heat exchangers are produced mainly in floor-standing boilers. In addition, cast iron does not tolerate sudden temperature changes — they can cause cracks.

Steel. Steel heat exchangers in heating boilers are the most widely used. Steel has a combination of high ductility and strength when exposed to high temperatures, is inexpensive, and can be easily processed at production stages. However, steel heat exchangers are susceptible to corrosion. As a result, they are not as durable.

Stainless steel. Stainless steel heat exchangers are rare in heating boilers, which is explained by the high cost of using this material. But they combine the advantages of both cast iron and steel. Stainless steel exhibits high corrosion resistance, resistance to thermal shocks, low inertia, and long service life.

Central heating flow

The diameter of the pipe for connecting the pipe through which the heated water enters the heating system from the boiler.

Diameters are indicated in inches. In some cases, it is allowed to connect a pipe of a different diameter through an adapter, but the best option is still a match in size. Among which models stand out for 3/4", 1", 1 1/4" and 1 1/2".

Central heating return

The diameter of the pipe for connecting the pipe through which the cooled water returns from the heating system to the boiler.

Diameters are indicated in inches. In some cases, it is allowed to connect a pipe of a different diameter through an adapter, but the best option is still a match in size.

Safety systems

Gas pressure drop. This protection system ensures that the boiler is switched off in the event of a critical drop in gas pressure, insufficient for the normal functioning of the burner. In the event of such a fall, the valve that supplies gas to the burner is closed and blocked. After the restoration of gas pressure, it also remains closed; it is necessary to open it and resume the gas supply manually.

Water overheating. A temperature sensor automatically turns off the boiler when the temperature of the water in the system is critically exceeded.

Flame loss. Flame loss protection is based on a sensor that monitors the combustion of gas and automatically stops its supply. It prevents the room from filling with gas and the possible tragic consequences of this.

Draft control. In boilers with an open combustion chamber, to maintain normal conditions in the room where such a boiler is installed, constant removal of products of combustion into the atmosphere is necessary. The lack of a normal draft in the chimney can lead to the accumulation of combustion products in the room. The draft protection system prevents this by automatically turning off the boiler when it detects the release of combustion products outside the chimney.

Power outage. Most modern boilers h...ave an electronic control system; in addition, many structural elements (pumps, valves, fans, etc.) are also powered by electricity. Thus, a power outage during the operation of the boiler will inevitably lead to an abnormal mode of operation, which is fraught with breakdowns and even accidents. To prevent such cases, a power outage protection system is installed, which completely stops the operation of the boiler in the event of a power outage. When the power supply is restored, the boiler needs to be restarted manually.

Water circulation failure. This protection system controls the normal movement of the water through the heating circuit. Water circulation failure can lead to overheating of some elements of the boiler and damage to it. To avoid this, if the circulation is disturbed, the system turns off the pump and shuts off the gas supply to the burner.

Frost protection. A system that controls the temperature in the heating circuit. Freezing of the liquid in the circuit disrupts the normal operation of the heating, which may require heating of the pipes and lead to system damage. To avoid this, when the water temperature drops below 5 °C, the burner is ignited, the circulation pump is activated, and the circuit warms up to a temperature of about 35 °C — thus preventing the formation of ice in the pipes.