USA
Catalog   /   Large Appliances   /   Cooker Hoods

Comparison Perfelli TL 6212 I 700 LED stainless steel vs Perfelli TL 6212 C S/I 650 LED stainless steel

Add to comparison
Perfelli TL 6212 I 700 LED stainless steel
Perfelli TL 6212 C S/I 650 LED stainless steel
Perfelli TL 6212 I 700 LED stainless steelPerfelli TL 6212 C S/I 650 LED stainless steel
Outdated ProductOutdated Product
TOP sellers
Product typebuilt-in (in cabinet)built-in (in cabinet)
Designwith sliding panelwith sliding panel
Specs
Modesextraction / recirculationextraction / recirculation
Motor power65 W110 W
Flow of air (motor)700 m³/h650 m³/h
Minimum noise level52 dB53 dB
Max. noise level61 dB63 dB
Number of speeds33
Number of motors11
Filtration
Grease filteraluminiumaluminium
Ability to install carbon filter
Features
LightingLED lamp
LED lamp /2x2W/
Controlspush-buttonspush-buttons
More specs
Duct diameter150 mm
Height (max)20 cm17.2 cm
Width59.7 cm60 cm
Depth29.7 cm
30.5 cm /with panel extended: 42.7 cm/
Color
Added to E-Catalogmarch 2023september 2019

Motor power

The power of the hood at maximum speed.

The more powerful the device, the more performant it is, usually. However, there is no rigid dependence here, and hoods of the same power may differ in actual performance. So it is worth evaluating power consumption in terms of power first of all: the lower this indicator, the more economical the device. And when evaluating performance, you need to look not so much at power as at the directly claimed flow of the air (see below).

Flow of air (motor)

The maximum flow of air or motor flow of air indicates the theoretical capability of the device. This parameter of the hood (motor) is measured during idle operation. By connecting the duct and working in the appropriate mode of extraction, the flow of air will be lower. However, high-performance motors will also give a high flow of air in extraction mode.

Minimum noise level

The volume at which the device operates in the quietest mode. Usually (but not necessarily) it is the minimum power mode.

The decibels in which the noise level is measured are non-linear units, so it is easiest to use comparison tables to estimate a specific value. Here is the simplest table for minimum noise in modern hoods:

— 20 dB. Almost inaudible. The volume of a whisper at a distance of 1 m, the sound background in an open field on a calm day.
— 30 dB. The whisper, the ticking of the clock. The maximum noise level allowed for residential premises at night.
— 40 dB. The volume of normal human speech. The maximum permissible sound background (permanent) for living quarters during the day.
— 50 dB. Conversation of several people in medium tones.
— 60 dB. Loud talk.
— 65 – 68 dB — background noise on a city street, a vacuum cleaner engine at a distance of 2 – 3 m. The highest noise level among modern hoods is typical for powerful performant models.

When choosing according to this indicator, note that, other things being equal, a quieter device will, accordingly, cost more.

Max. noise level

The level of noise produced by the hood in the loudest mode of operation. Usually (but not necessarily) it is the maximum power mode. It affects the comfort during operation of the device, so quiet hoods will be more preferable, but also more expensive.

The decibels in which the noise level is measured are non-linear units, so it is easiest to use comparison tables to estimate a specific value. Here is the simplest table for the values relevant in this case:

— 35 dB. The volume of a conversation in an undertone (but not a whisper). The lowest maximum noise value in modern hoods. Devices with such characteristics are almost guaranteed not to cause inconvenience: such noise is often blocked by other sounds, for example, the background noise of the street in an open window.
— 40 dB. The volume of a normal conversation. The maximum noise level allowed in a residential area during the day. If the hood is bought for home use, and it is supposed to be turned on often and for a long time, the noise level in the selected device shouldn't exceed this indicator.
— 50 dB. Conversation volume at medium tones.
— 60 dB. Raised conversation.
— 70 dB. Sound background on a busy street, in a crowd of people talking loudly, the sound of a vacuum cleaner motor at a distance of 2 – 3 m.
— 75 dB. Scream or loud laughter at a distance of about a metre.
— 78 – 79 dB. Loud mechanical alarm clock, motorcycle o...r truck engine. The highest level in modern consumer-grade hoods.

Note that the actual comfort of using the device depends not only on the volume but also on the timbre (tonality) of the noise: for example, a low, even rumble is generally perceived easier than high frequencies with clanging notes. If the hood installation is unsuccessful, the actual noise level may be higher than stated in the specifications. For example, additional noise can be caused by the hum of air in the ducts or rattling from the contact of the vibrating body with the wall. However, when choosing, it is worth focusing on the noise level claimed in the specifications.

Duct diameter

The duct diameter characterizes the size of the hood outlet to which the ducts are connected. The standard is either 120 mm or 150 mm. In many cases, an adapter from one diameter to another can additionally be included with the device. However, when replacing the hood with a new one, it is still better to operate with the existing pipe diameter and not use adapters.

Height (max)

The height of the entire hood structure is from the lower edge to the upper part of the body (the point of connection of the external air duct). For hoods with an adjustable design that allows you to change the height of the case, the maximum height is the size of the device in the unfolded state; in the case of non-adjustable hoods, this means a correspondingly constant overall height. When choosing a hood in height, it is worth proceeding from two points:

1. The optimal height of the air intake above the hob is 60-80 cm. This height allows the hood to capture kitchen fumes effectively and, at the same time, gives enough space to work with the hob.

2. Between the hood body and the ceiling, a clearance is required for connecting an external air duct.