USA
Catalog   /   Home & Renovation   /   Autonomous Power Supply   /   UPS

Comparison APC Back-UPS 850VA BE850G2-GR 850 VA vs APC Back-UPS 850VA BE850G2-RS 850 VA

Add to comparison
APC Back-UPS 850VA BE850G2-GR 850 VA
APC Back-UPS 850VA BE850G2-RS 850 VA
APC Back-UPS 850VA BE850G2-GR 850 VAAPC Back-UPS 850VA BE850G2-RS 850 VA
Outdated ProductOutdated Product
TOP sellers
Main
USB-C and USB A ports for charging gadgets.
Eight euro sockets. USB-C and USB A ports for charging gadgets. Manage and monitor status through the PowerChute Personal Edition application.
Typebackback
Form factorregular (extension)regular (extension)
Full load operating time2.3 min2.3 min
Half load operating time9.8 min9.8 min
Switching to battery6 ms6 ms
Input
Input voltage1 phase (230V)1 phase (230V)
Input voltage range180 – 266 V180 – 266 V
Max. current6 A6 A
Input frequency47 – 63 Hz47 – 63 Hz
Bypass (direct connection)is absentis absent
Output
Output voltage1 phase (230V)1 phase (230V)
Max. output power850 VA850 VA
Rated output power520 W520 W
Efficiency99.3 %99.3 %
Output waveformsimilar to a sinusoid (approximated)similar to a sinusoid (approximated)
Output frequency47 – 63 Hz47 – 63 Hz
Redundant sockets66
Non-redundant sockets22
Socket typetype F (Schuko)type F (Schuko)
Charging USB A ports
/2.4 А/
/2.4 А/
USB-C for charging1 pcs1 pcs
Battery
Battery typelead acid
Supplied battery(s) capacity9 Ah7.7 Ah
Batteries11
Full charge time960 min960 min
Cold start
Protection
Protection
short circuit protection
overload protection
noise filtering
data line protection
sound alarm
short circuit protection
overload protection
noise filtering
data line protection
sound alarm
Fuseautoauto
Surge protection310 J310 J
Control interfaces
USB
USB
General
Operating temperature0 – 40 °C0 – 40 °C
Noise level45 dB45 dB
Dimensions (HxWxD)120x365x130 mm120x365x130 mm
Weight4.5 kg4.5 kg
Added to E-Catalogaugust 2022december 2019

Battery type

- Lead acid. Structurally, lead-acid batteries are based on a combination of electrodes made of lead compounds immersed in a liquid electrolyte, the role of which is played by an aqueous solution of sulfuric acid. The advantages of this type are simplicity and low cost, low self-discharge, no "memory effect" and maintaining performance in a wide temperature range. At the same time, the less charge remains in such batteries, the less current they produce. Also, lead-acid batteries are afraid of deep discharges, take a long time to charge, have large dimensions and weight in the context of other types.

- Lead-acid (AGM). An advanced type of lead-acid battery with an electrolyte in a jelly-like state. The gel electrolyte provides maximum contact with the negative and positive plates while maintaining a uniform consistency throughout the volume. AGM batteries impress with their high reliability, low self-discharge, deep discharge resistance and long service life. However, they are sensitive to charge quality, short circuits and negative temperatures.

— Li-Ion. Lithium-ion batteries have a high capacity with small dimensions and weight. They are not subject to the “memory effect”, they are able to charge quite quickly, they can boast of an excellent reserve for charge-discharge cycles. Li-Ion batteries also have disadvantages - first of all, it is sensitivity to low or high temperatures, and when overloaded, such a battery can catch fire or even explode. Howeve...r, due to the use of embedded controllers, the likelihood of such "accidents" is extremely small and, in general, the advantages of this technology significantly outweigh the disadvantages.

Supplied battery(s) capacity

The capacity of the battery installed in the UPS. For models with multiple batteries, this is both the total working capacity and the capacity of each individual battery: the batteries in such devices are usually connected in series, so that their total capacity corresponds to the capacity of each individual cell.

Theoretically, a higher battery capacity means the ability to power loads of a given capacity for longer. However, in fact, this parameter is more of a reference than practically significant. The fact is that the actual amount of energy stored by the battery depends not only on the capacity in amp-hours, but also on the voltage in volts; this voltage is often not specified in the characteristics, despite the fact that for accurate calculations it must be known. So when choosing, you should focus on more "close to life" characteristics — first of all, on the directly claimed operating time in different modes (see above).

Cold start

The ability to turn on the uninterruptible power supply in the "cold start" mode.

A cold start is a turn-on mode in which there is no external power, and the load connected to the UPS is powered immediately from the uninterruptible battery (which, of course, must be charged). This mode is especially useful in emergency cases — for example, if you urgently need to print a document, but there is no light.
APC Back-UPS 850VA BE850G2-RS often compared