USA
Catalog   /   Home & Renovation   /   Autonomous Power Supply   /   UPS

Comparison Legrand Keor SP 2000VA IEC GR 2000 VA vs Legrand Keor SP 2000VA IEC 2000 VA

Add to comparison
Legrand Keor SP 2000VA IEC GR 2000 VA
Legrand Keor SP 2000VA IEC 2000 VA
Legrand Keor SP 2000VA IEC GR 2000 VALegrand Keor SP 2000VA IEC 2000 VA
Outdated Product
from $613.00 
Expecting restock
TOP sellers
Typebackback
Form factorstandard (Tower)standard (Tower)
Switching to battery6 ms6 ms
Input
Input voltage1 phase (230V)1 phase (230V)
Input voltage range170 – 280 V170 – 280 V
Bypass (direct connection)is absentis absent
Output
Output voltage1 phase (230V)1 phase (230V)
Peak output power2000 VA2000 VA
Rated output power1200 W1200 W
Efficiency98 %98 %
Output waveformsimilar to a sinusoid (approximated)similar to a sinusoid (approximated)
Output frequency50/60 Hz50/60 Hz
Redundant sockets2
Socket typetype F (Schuko)
Reserved C13/C14 connectors26
Charging USB A ports11
Battery
Total battery capacity9 Ah9 Ah
Number of batteries22
Full charge time360 min360 min
Cold start
Protection
Protection
short circuit protection
overload protection
sound alarm
short circuit protection
overload protection
sound alarm
Fusemeltingmelting
Control interfaces
USB
USB
General
Operating temperature0 – 40 °C0 – 40 °C
Noise level40 dB40 dB
Dimensions (HxWxD)173x148x380 mm173x148x380 mm
Weight10.3 kg10.3 kg
Added to E-Catalogapril 2021april 2021

Redundant sockets

The number of outlets connected to the power reserve(battery) provided in the design of the UPS. In order for the UPS to fulfill its main role (providing a backup power in case of power outages), the corresponding electrical appliances must be connected to these outlets. The sockets have a standard shape and are compatible with the vast majority of popular 230 V plugs.

At a minimum, the UPS has 1 or 2 outlets and, in more advanced ones, there may be 3 or more.

Socket type

A socket for a specific type of plug in the UPS design.

Type F (Schuko). A traditional European socket with two round holes in the center and grounding contacts in the form of two metal brackets (at the top and bottom of the socket). The term Schuko stuck to this type of socket due to the abbreviation from the German Schutzkontakt - protective contact.

Type E (French). The French style socket has two round holes and a protruding ground pin just above them in the center. The standard has become widespread in France, Poland and Belgium (along with the traditional type F sockets).

Type G (British). The plug for such sockets consists of two flat horizontal pins and one flat vertical pin for grounding. The standard is found mainly in the countries of the United Kingdom, Malta, Cyprus, Singapore and Hong Kong.

Type B (American). American-style sockets are designed for plugs with two flat prongs and a semicircular grounding contact. Type B is widely used in regions with voltage 110 - 127 V - USA, Japan, Saudi Arabia, etc.

Reserved C13/C14 connectors

Number of C13/C14 connectors with power reserve provided in the UPS design.

Electrical appliances connected to connectors with a reserve are insured against a power failure in the network - in this case they switch to the battery. The C13/C14 connector itself is also known as a “computer socket”; it supplies the same 230 V as a regular household network, but is not compatible with plugs for traditional sockets, because uses three flat contacts. However, there are adapters between these standards.

At a minimum, the UPS is provided with 1, 2 or 3 C13/C14 connectors for one workstation. In more advanced, so to speak office ones, the number of C13/C14 connectors may be greater - 4 ports, 6 connectors, 8 and even more
Legrand Keor SP 2000VA IEC often compared