USA
Catalog   /   Climate, Heating, Water Heating   /   Heating & Cooling   /   Air Conditioners   /   Mitsubishi Heavy

Mitsubishi Heavy SRK52HE/SRC52HE 52 m²

Photos - Air Conditioner Mitsubishi Heavy SRK52HE/SRC52HE 52 m²
Outdated Product
$5,636.00
Type: split system; Operating modes: cooling/heating/dehumidification/ventilation; Room area (m²): 52; Power consumption (cooling/heating): 1730/1490; Cooling capacity (W): 5100; Heating capacity (W): 5800; Noise level (max/min) (dB): 43/36; Functions: inverter; automode; timer; night mode
add to listmy lists
Mitsubishi Heavy SRK52HE/SRC52HE 52 m²
Type:split, wall
Recommended area:52 m²
Consumption:1730/1490 W
Functions:night mode
All specifications
Specifications SRK52HE/SRC52HE
Colour
Typesplit system
Installationwall
In boxindoor unit
outdoor unit
Performance
Operating modescooling/heating/dehumidification/ventilation
Recommended room area52 m²
Power consumption (cooling/heating)1730/1490 W
Cooling capacity5100 W
Heating capacity5800 W
Noise level (max/min)43/36 dB / outdoor unit — 65 dB /
Features
Functionsinverter
automode
timer / 24 hours /
night mode
auto restart
self-diagnosis
Specs
Display+
Refrigerant typeR22
Filtersantibacterial
anti-allergic
deodorizing (charcoal) / photocatalytic /
General specs
Indoor unit dimensions (WxHxD)1098х318х248 mm / weight — 15 kg /
Dimensions of window/outdoor unit (WxHxD)850х640х290 mm / weight — 47 kg /
Added to E-Catalogapril 2009
Information in model description is for reference purposes.
Before buying always check characteristics and configuration of product with online store manager
Catalog Mitsubishi Heavy 2024 - new products, best sales and most actual models Mitsubishi Heavy.
Additional features air conditioner Mitsubishi Heavy SRK52HE/SRC52HE:
  • 3 heating modes
  • Boost Mode
  • Automatic blinds
  • Blinds memory
Good to know:

Three heating functions
"Hot Start" (Hot start) delays the flow of cold air into the room when the air conditioner is turned on. "Hot Spurt" ("Hot jet") provides accelerated access to the set temperature during heating operation. The "Hot Keep" function prevents cold air from entering the room during defrosting.

Boost Mode
The air conditioner runs at maximum capacity for 15 minutes. This mode is convenient when you need to quickly reach the desired temperature.

air spiral
The oscillatory movements of the blinds lead to a coma, that the air flow "spins", due to which it reaches the farthest corners of the room.

Self-diagnosis function
In the event of an air conditioner failure, the microcomputer automatically starts the self-diagnosis function, after which a malfunction code is displayed on the display.
Filters