Drazice OKC 200 NTR/BP
Outdated Product A high-performance storage water heater of the middle class, the model has a cylindrical shape and is used as an additional external module in conjunction with a heating boiler. A heat carrier is passed through a powerful heat exchanger of 32 kW, giving off part of the energy to the contents of the tank, enameled from the inside, protected from overpressure. At the same time, the tank capacity of this particular modification is 208 liters, although within the framework of the series, the manufacturer also produces solutions with volumes from 148 to 945 liters. It takes only 23 minutes to heat water to 50 °C, and the maximum temperature can reach as much as 90 °C, so the Drazice OKC 200 NTR / BP boiler can even serve uninterrupted shower cabins of industrial enterprises. Due to a decent mas...s, it is advisable to place the unit on the floor or on a special stand, since the strength of the brickwork may not be enough to hold the fasteners. Rust inside is practically not formed due to the magnesium anode actively participating in electrochemical processes, which should be periodically replaced with a new copy during scheduled cleanings from sediment accumulated at the bottom. |
Drazice OKC 200 NTR/BP | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
A high-performance storage water heater of the middle class, the model has a cylindrical shape and is used as an additional external module in conjunction with a heating boiler. A heat carrier is passed through a powerful heat exchanger of 32 kW, giving off part of the energy to the contents of the tank, enameled from the inside, protected from overpressure. At the same time, the tank capacity of this particular modification is 208 liters, although within the framework of the series, the manufacturer also produces solutions with volumes from 148 to 945 liters.
It takes only 23 minutes to heat water to 50 °C, and the maximum temperature can reach as much as 90 °C, so the Drazice OKC 200 NTR / BP boiler can even serve uninterrupted shower cabins of industrial enterprises. Due to a decent mass, it is advisable to place the unit on the floor or on a special stand, since the strength of the brickwork may not be enough to hold the fasteners. Rust inside is practically not formed due to the magnesium anode actively participating in electrochemical processes, which should be periodically replaced with a new copy during scheduled cleanings from sediment accumulated at the bottom.
Before buying always check characteristics and configuration of product with online store manager
Catalog Drazice 2024 - new products, best sales and most actual models Drazice.