Catalog   /   Climate, Heating, Water Heating   /   Heating & Boilers   /   Boilers   /   Wichlacz

Wichlacz GK 17 17 kW

Photos - Boiler Wichlacz GK 17 17 kW
Outdated Product
Energy source: solid fuel; Installation: floor; Type: single-circuit (heating only); Heating area (m²): 136; Long burning; Heat output (kW): 17; Coolant max. T (°C): 90; Efficiency (%): 89; Combustion chamber: open (atmospheric); Firebox size: Dimensions (mm): 1180x540x710; Weight (kg): 340
add to listmy lists
Wichlacz GK 17 17 kW
Energy source:solid fuel
Mount:floor, single-circuit
Boiler power:17 kW, area ~ 136 m²
Combustion chamber:open
All specifications
Specifications GK 17
Main
Energy sourcesolid fuel
Installationfloor
Typesingle-circuit (heating only)
Heating area136 m²
Long burning
Technical specs
Heat output17 kW
Power supply230 В
Power consumption80 W
Coolant max. T90 °С
Heating circuit max. pressure3 bar
Consumer specs
Circulation pump
Boiler specs
Efficiency89 %
Combustion chamberopen (atmospheric)
Connections
Central heating flowDN50
Central heating returnDN50
Safety
Safety systemswater overheating
More specs
Dimensions (HxWxD)1180x540x710 mm
Weight340 kg
Added to E-CatalogSeptember 2015
The information in the model description is for reference purposes.
Always clarify the specifications and configuration of the product with the online store manager before purchasing.
Catalog Wichlacz 2026 - new arrivals, bestsellers, and the most relevant models Wichlacz.
0
0
3
5
boiler-bomb!
15 April 2016 
relatives from Uzbekistan called Shakhrisabz - they have very high-temperature coal and all the boilers for one winter and the grate burns out first of all - and the cast iron does not withstand
the principle of flowing grate is the bomb! Cast iron grate is resting!
want a longer burn time
use Wichlacz GK 17 month or more i recommend it should buy
anti-crisis boiler
14 April 2016 
burn any very foul coal
Gorinnya on one zavantazhenni 48 years
on firewood more like 4 years in me do not burn, that and that with a stretch
use Wichlacz GK 17 month or more i recommend it should buy
install a room heat regulator
19 April 2016 
i installed a room temperature controller and automatically regulate my temperature in the house from the frost outside and save up to 50% of wood. My neighbor has the same house, but the amount of wood required is twice as much
automatic temperature control in the house and great savings in firewood
neighbor's wife is jealous
use Wichlacz GK 17 month or more i recommend it should buy
3 out of 8 user review(s) shown
5 more user review(s)