USA
Catalog   /   Climate, Heating, Water Heating   /   Heating & Boilers   /   Heat Pumps   /   Hisense

Hisense AFM/AFW-48 14 kW

Photos - Heat Pump Hisense AFM/AFW-48 14 kW
Outdated Product
Heat source: air-water; Suitable for: heating and DHW; In box: hydromodule; outdoor unit; Operating mode: heating and cooling; Max. heat output: 14; Heat output (~ 0 °C): 11.2; Max. cooling output: 14; Power consumption (heating) (kW): 3.21; Electric heater (kW): 3; Compressor: inverter: inverter
add to listmy lists
Hisense AFM/AFW-48 14 kW
Main
Heat sourceair-water
Suitable forheating and DHW
In box
In boxindoor unit (hydromodule)
outdoor unit
Specs
Operating modeheating and cooling
Max. heat output14 kW / at A7/W35 °C /
Heat output (~ 0 °C)11.2 kW / at A2/W35 °C /
Max. cooling output14 kW
Power consumption (heating)3.21 kW / 3.92 kW (heating/cooling) /
Power source230 V
Electric heater3 kW
Minimum operating temperature-23 °C
Max. water temperature55 °C
Compressorinverter
Energy efficiency
t°C outside7
Supply t°C35 °C
COP4.36
t°C outside-7
Supply t°C35 °C
COP2.14
More specs
RefrigerantR410A
Noise level54 dB
Country of brand originChina
Dimensions890x520x320 mm
Outdoor unit dimensions1380x950x370 mm
Hydromodule weight58 kg
Outdoor unit weight103 kg
Added to E-Catalogjanuary 2019
Information in model description is for reference purposes.
Before buying always check characteristics and configuration of product with online store manager
Catalog Hisense 2024 - new products, best sales and most actual models Hisense.
Filters
Models
Brands
(heat source) 
air-water 
Out of stock
AFM/AFW-48