Fondital Victoria Compact CTFS 24 AF 24 kW
230 V

Photos - Boiler Fondital Victoria Compact CTFS 24 AF 24 kW 230 V
Outdated Product
Energy source: gas; Installation: wall; Type: dual-circuit (heating and DHW); Heating area (m²): 180; Heat output (kW): 24; Coolant max. T (°C): 83; DHW max. T (°C): 58; Performance (ΔT=25 °C) (L/min): 11.3; Efficiency (%): 93; Combustion chamber: closed (turbocharged); Firebox size: Dimensions (mm): 700x400x250
add to listmy lists
Fondital Victoria Compact CTFS 24 AF 24 kW
230 V
Energy source:gas
Mount:wall, dual-circuit
Boiler power:24 kW, area ~ 180 m²
Combustion chamber:closed, flue 80/80 mm
DHW temperature:up to 58 °С
All specifications
Specifications Victoria Compact CTFS 24 AF
Main
Energy sourcegas
Installationwall
Typedual-circuit (heating and DHW)
Heating area180 m²
Technical specs
Heat output24 kW
Power supply230 В
Power consumption140 W
Coolant max. T83 °С
Heating circuit max. pressure3 bar
DHW circuit max. pressure8 bar
Consumer specs
DHW max. T58 °С
Performance (ΔT=25°C)11.3 L/min
"Summer" mode
Circulation pump
Boiler specs
Efficiency93 %
Combustion chamberclosed (turbocharged)
Flue diameter80/80 mm
Inlet gas pressure20 mbar
Max. gas consumption2.7 m³/h
Expansion vessel capacity6 L
Coolant performance550 L/h
Connections
Mains water intake1/2"
DHW flow1/2"
Gas supply1/2"
Central heating flow3/4"
Central heating return3/4"
Safety
Safety systemsgas pressure drop
water overheating
flame loss
water circulation failure
frost protection
More specs
Dimensions (HxWxD)700x400x250 mm
Weight28.4 kg
Added to E-CatalogDecember 2012
The information in the model description is for reference purposes.
Always clarify the specifications and configuration of the product with the online store manager before purchasing.
Catalog Fondital 2026 - new arrivals, bestsellers, and the most relevant models Fondital.
If you plan to leave it unattended for more than a week, I do not recommend it.
9 September 2013 
The entire installation is for it, I won’t redo it yet. I’ll enter this river twice, buy another one, and put it in reserve. Buderos installed as the main one.
It works correctly, adjusting the flame intensity to the specified coolant temperature parameters. Minimum switching on and off of the burner, which ensures high temperature comfort in the room. Almost silent. Very economical, in comparison with analogues. It is not difficult to install yourself.
Unreliable. The air valve leaks. The heat exchanger often gets air-locked at the outlet, resulting in "emergency" shutdown due to overheating. The turbo-fan for combustion product removal failed in the third month of operation. Despite having a voltage stabilizer installed specifically for it, a power outage and subsequent power restoration burned out the capacitor in the electronic control board (simultaneously, the 2A fuse also blew). After replacing both parts, it came back to life for three minutes, but the burner did not resume correct operation. As a result, in the closed combustion chamber, an explosion of the accumulated gas occurred for some reason (the fan was operating). I took it to the dump, didn’t dare to attempt another repair. It lasted for one season, costing 23,000 rubles per year, which is somewhat costly...
Dmitriyuse Fondital Victoria Compact CTFS 24 AF more than year
try another manufacturer
16 October 2016 
after the first year of operation, problems began with the thrust sensor, I had to remove it once a week, disassemble and clean the contacts inside. Surprisingly, after a month of these ordeals, the problem disappeared). From the very beginning, the heat exchanger tube (cold water inlet) was leaking, there was a microcrack in the tube itself, it was soldered. After six years of operation, I washed the heat exchanger from scale, and it leaked in several more places. Judging by the announcements on Avito, the heat exchanger in this boiler is a weak point. Also, the temperature of the water in the water supply circuit is not regulated, boiling water is pouring. The plastic round lining on the exhaust pipe, which is placed on the street, also fell apart, and the plastic clamp that tightens the straight section of the exhaust pipe and the corner exit of their boiler fell apart.
quiet, economical, does the job
low quality materials. It seems to work, but there is always something to finish
use Fondital Victoria Compact CTFS 24 AF month or more i recommend it don't buy
Apparently I was lucky)
5 February 2019 
Works for 7 years continuously! During the entire period of service from repairs: replacing the expansion tank with ours (with your own hands). Nothing ever broke! I didn't get into it at all. Taking into account the other comments, I can say that I was probably lucky =)
Automaticity, service life
Without good water pressure - it doesn't work
use Fondital Victoria Compact CTFS 24 AF more than year
Add Review
Model differences:
  • Model Victoria Compact CTFS 24 AFclosed combustion chamber
  • Model Victoria Compact СTN 24 AFopen combustion chamber