Dark mode
USA
Catalog   /   Climate, Heating, Water Heating   /   Heating & Boilers   /   Heat Pumps   /   Fado

Fado NTS16F3 16 kW

Photos - Heat Pump Fado NTS16F3 16 kW
Photos 4
Expecting restock
Heat source: air-water; Suitable for: heating and DHW; In box: hydromodule; outdoor unit; Operating mode: heating only; Max. heat output: 16.2; Max. cooling output: 14; Power consumption (heating) (kW): 3.67; Power consumption (cooling): 5.71; EER: 2.45; Compressor: inverter: inverter
add to listmy lists
Fado NTS16F3 16 kW
Main
Heat sourceair-water
Suitable forheating and DHW
In box
In boxindoor unit (hydromodule)
outdoor unit
Specs
Operating modeheating only
Max. heat output16.2 kW / at A7/W35 /
Max. cooling output14 kW / at A35/W12 /
Power consumption (heating)3.67 kW
Power consumption (cooling)5.71 kW
EER2.45
Power source400 V
Minimum operating temperature65 °C
Max. water temperature-25 °C
Compressorinverter
Energy efficiency
t°C outside7
Supply t°C35 °C
COP4.41
Energy efficiency class (W35)A+++
Energy efficiency class (W55)A++
t°C outside-7
Supply t°C35 °C
COP2.61
More specs
Control via smartphone+
RefrigerantR32
Outdoor unit noise level49 dB / at A-7/W35 /
Country of brand originItaly
Dimensions909x465x273 mm
Outdoor unit dimensions860x1040x432 mm
Hydromodule weight41 kg
Outdoor unit weight93 kg
Added to E-Catalogdecember 2024
Information in model description is for reference purposes.
Before buying always check characteristics and configuration of product with online store manager
Filters
Models
Brands
(heat source) 
air-water 
Out of stock
NTS16F3